background image

                                                                                                    - 

  -                                                                XM095-V1.1-NR           

                 

Control Board 

The Control Board offers several features: you can simply set the starting address, switch on and off the lamp, run 
the pre-programmed program or make a reset. 
The main menu is accessed by pressing the 

Mode/esc

-button until the display starts flashing. Browse through the 

menu by pressing the 

Up

-button or 

Down

-button. Press the 

Enter

-button in order to select the desired menu. You 

can  change  the  selection  by  pressing  the 

Up

-button  or 

Down

-button.  Confirm  every  selection  by  pressing  the 

Enter

-button. You can leave every mode by pressing the 

Mode/esc

-button. The functions provided are described in 

the following sections.

 

Default settings shaded 
 

Fu

nc

ti

on

 M

od

Set DMX Address 
Value Display 
Set To Slave 
Auto Program 
Music Control 

A001~AXXX 
PAN…… 
Slave1,Slave2,Slave3 
Master / Alone 
Master / Alone 

DMX address setting 
DMX value display 
Slave setting 
Auto program 
Music control 

In

fo

rm

at

io

Time Information 

Current Time 
Total Run Time 
Total Lamp Time 
Lamp Off Time 
Clear Lamp Time 

XXXX(Hours) 
XXXX(Hours) 
XXXX(Hours) 
XXXX(Minute) 
ON/OFF 

Power on running time 
Fixture running time 
Lamp running time 
Lamp off time 
Clear lamp time 

Temperature Info 

Base Temperature 
Head Temperature 

XX 

/

 

XXX

/

 

Temperature  on  the  display 
board of the base 
Temperature in the head 

Software Version 

Ver1.1

 

Software version of each IC 

La

m

C

on

tr

ol

 

Lamp On or Off 
Automatic La-On 
Lamp On Via DMX 
Lamp Off Via DMX 
Lamp Off No DMX 
Lamp On at Temp. 
Lamp Off at Temp. 

ON/OFF 
ON/OFF 
ON/OFF 
ON/OFF 
OFF, 0FF~19M 
20~79

,45

  /68~174

℉ 

113

 

80

~

139

,

 130

  /176~282

℉,

 266

 

Lamp on/off 
Lamp  on/off  when  Power 
on 
Lamp on via DMX 
Lamp off via DMX 
Lamp off if no DMX 
Lamp restart at temp. 
Lamp off at temp. 

Pe

rs

on

al

it

Status Settings 

Address via DMX 
No DMX Status 
Pan Reverse 
Tilt Reverse 
Fine Resolution 
Pan Degree 
Dimmer Speed 
Feedback 
Movement Speed 
Mic Sensitivity 

ON/OFF 
Close/Hold/Auto/Music 
ON/OFF 
ON/OFF 
ON/OFF 
630/540 
Slow/Quick 
ON/OFF 
Speed 1~ 4 
0~99% 

Add. via DMX 
Auto run if no DMX 
Pan Reverse movement 
Tilt Reverse movement 
Fine resolution switch 
Pan Degree Select 
Dimmer Speed Select 
Movement Feedback switch 
Movement Mode Select 
Sensitivity of Mic. 

Service Setting 

Service Password 
Fan Voltage   
Gobo Speed 

Password=XXX 
High/Low 
Quick/Slow 

Service Code

=050

 

Fan Voltage Select   
Gobo Change Speed 

Fans Control 

Auto Fans Speed 
High Fans Speed 
Low Fans Speed 

Fans Speed Mode Select 

Содержание CL 575S-E

Страница 1: ...PROFESSIONAL MOVING HEAD USER MANUAL CL 575S E KEEP THIS MANUAL FOR FUTURE NEEDS...

Страница 2: ...sound activated via built in microphone Pan and tilt movement 8 and 16 bit resolution For smooth and precise motion Movement Pan 540 630 optional Tilt 260 Speed of pan tilt movement adjustable Scan p...

Страница 3: ...tion it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual 1 Projector head 2 Objective lens 3 Yoke 4 Ventilation fan 5 Base 6 Control...

Страница 4: ...onto combustible substances Fixtures cannot be installed on combustible substances keep more than 50cm distance with wall for smooth air flow so there should be no shelter for fans and ventilation for...

Страница 5: ...result of unprofessional operation Please use the original packaging if the device is to be transported For safety reasons please be aware that all modifications on the device are forbidden If this de...

Страница 6: ...below 1 3 2 A B C D Please remember the lamp is not a hot restrike type you must wait for approximately 15 minutes after having turned off the lamp before you can turn it back on again D o not operat...

Страница 7: ...le m aterial w ithin a distance of min 0 5m Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safet...

Страница 8: ...Pull the safety rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw DMX 512 control connec...

Страница 9: ...channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct nu...

Страница 10: ...e Fixture running time Lamp running time Lamp off time Clear lamp time Temperature Info Base Temperature Head Temperature XX XXX Temperature on the display board of the base Temperature in the head So...

Страница 11: ...m Select Programs Auto Pro Part 1 Auto Pro Part 2 Auto Pro Part 3 Program 1 10 Program 1 Program 1 10 Program 2 Program 1 10 Program 3 Select programs to be run Edit Program Program 1 Program 10 Progr...

Страница 12: ...ff Clear lamp time With this function you can clear the running time of the lamp Please clear the lamp time every time you replace the lamp Select Clear lamp time by turning the encoder Press the enco...

Страница 13: ...r DMX 16 channel of internal program value 60 79 Select ON by turning the encoder if you wish to enable this function or OFF if you don t Lamp Off if no DMX With this function you can select to switch...

Страница 14: ...ement or tilt movement Pan Degree With this function you can select pan degree for 630 or 540 Dimmer Speed With this function you can adjust the dimming speed Feedback With this function you can feedb...

Страница 15: ...erent channels list by different sequence For example after the user enter this manual if select Auto Program CH 16 means in this User s mode the Dimmer is in Channel 12 User mode With this function y...

Страница 16: ...rn to the main menu 3 Program selection for Auto Pro Part Select Edit program by turning the encoder Press the Enter button to confirm Select Select programs by turning the encoder Press the Enter but...

Страница 17: ...s Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture INSTRUCTIONS ON USE DMX channel...

Страница 18: ...5 shake slow to fast 170 189 Gobo 6 shake slow to fast 190 255 Rot gobo wheel cont rotation slow to fast Channel 3 Rotating gobo index rotating gobo rotation 0 127 Gobo indexing 128 189 Forwards gobo...

Страница 19: ...prism Prism Gobo macros 0 3 open 4 63 Forwards rotation from fast to slow 64 67 No rotation 68 127 Backwards rotation from slow to fast 128 135 Macro 1 136 143 Macro 2 144 151 Macro 3 152 159 Macro 4...

Страница 20: ...l 13 Iris 0 191 Max diameter to Min diameter 192 223 Pulse opening fast to slow 224 255 Pulse closing slow to fast Channel 14 Frost 0 191 Frost 0 100 192 223 Pulse opening fast to slow 224 254 Pulse c...

Страница 21: ...1 If there are some errors on channel 1 channel 5 channel 6 at the same time you may see the error message Color Er PAN movement 8bit Er TILT movement 8bit Er flash repeated for 5 times and then the...

Страница 22: ...or is defective or its driver circuit on the main PCB The color wheel 2 is not located in the default position after the reset Prism Er Prism error This message will appear after the reset of the fixt...

Страница 23: ...FICATIONS Power supply 100VAC 50Hz 120VAC 50Hz 208VAC 50Hz 220VAC 50Hz 230VAC 50Hz 240VAC 50Hz 100VAC 60Hz 120VAC 60Hz 208VAC 60Hz 220VAC 60Hz 230VAC 60Hz 240VAC 60Hz Power consumption max 780W Lamp M...

Отзывы: