6
Cyclone Insert Installation - English
MOUNTING HEIGHTS AND CLEARANCE
• The hood should be installed at 28” minimum above the
cooking surface. If pairing your range hood with a gas
stove minimum mounting height must be 30” above the
cooking surface.
WARNING
Minimum mount height between range top to hood bottom should
be no less than 28” for electric or ceramic stoves, and no less than 30”
for gas stoves. The maximum mount height should be no more than
36”. The hood must be installed at the correct mounting height. Hoods
mounted too low could result in heat damage. Hoods mounted too
high, on the other hand, will be less effective and performance may
suffer.
Check your ceiling height and the hood height maximum before
you select your hood.
Hood installation height above cook top is the user’s preference.
The lower the hood is above the cook top the more efficient it will
be in drawing out cooking odors, grease and smoke.
WIRING INSTALLATION
Min:
Ceramic/Electric
28”
Gas
30”
Max:
36”
36”
Grounding Instructions
This appliance must be grounded.
This appliance is equipped with a cord having a grounding wire or
with a plug having grounding wire. The grounding wire must be
grounded properly in the junction box or the plug must be plugged
into an outlet that is properly installed and grounded.
1. Connect the power line ground wire to the green ground wire
supplied with the hood.
2. Connect the black power wire to the black wire supplied with
the hood.
3. Connect the white neutral wire to the white wire supplied with
the hood.
Install the Electrical Power Supply
Install a junction box inside the upper corner of the cabinet. For
the model SS13024, it should be installed at a minimum of 8” away
from the center of the cabinet and 12” above the bottom of the
cabinet. For the models SS13030, BX21228/BX21528, BX600/
CLX60, it should be installed at a minimum of 11” away from the
center of the cabinet, and 12” above the bottom of the cabinet. For
the model BX21234/BX21534, it should be installed at a minimum
of 13” away from the center of the cabinet, and 12” above the
bottom of the cabinet.
Green: Ground
White: Neutral
Black: Power
This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected
by a circuit breaker or time delay fuse.
Ceramic/Electric 28”
Max:
36”
Gas
30”
Min: