1.  Supplied Parts
2.  Safety Precautions
3.  Product General
4.  System Configuration before installing Modbus Interface Module
5.  How to Install
6.  Modbus Protocol

1. Confirming the supplied parts

Check that the box includes the following part(s) in addition to this installation manual:
CL-MC03** Series Modbus Interface Module

2. Safety Precautions

·  

Thoroughly read the following safety precautions before use.

·  

Hazards that can occur from incorrect handling are classified by the symbols below: 

Warnin

g

Cau

ti

on

No

ti

ce

I

n

di

cate a 

p

oten

ti

a

lly 

haza

rd

ous s

i

tua

ti

on 

w

h

i

ch, 

i

f not avo

id

e

d

, cou

ld

 

r

esu

l

i

d

eath o

r

se

ri

ous 

i

nju

ry.

I

n

di

cate a 

p

oten

ti

a

lly 

haza

rd

ous s

i

tua

ti

on 

w

h

i

ch, 

i

f not avo

id

e

d

, cou

ld

 

r

esu

l

i

n m

i

no

r

 o

mo

d

e

r

ate 

i

nju

ry

I

t cou

ld

 a

l

so 

b

e use

d

 to a

l

e

r

t a

g

a

i

nst unsafe 

pr

ac

ti

ces.

I

n

di

cates a s

i

tua

ti

on that cou

ld

 

r

esu

l

i

n equ

ip

ment o

r

 

pr

o

p

e

r

t

y-d

ama

g

e on

ly

 acc

id

ents.

·  

After reading this manual, keep this manual for future reference. When the device is reinstalled or

 repaired, give this manual to those who provide these services. When the user changes, make sure
 that the new user receives this manual.

Warning

·  Only a dealer or qualified technician should install, relocate, reinstall, or repair the device.

    Improper installation or repair may result in electrical shock or fire.

·  Properly install the device on a stable, load-bearing surface. 

    Device installed on an unstable surface may fall and cause injury.

Содержание CL-MC03** Series

Страница 1: ...Modbus Interface Module INSTRUCTION MANUAL Model Document Rev 1 CL MC03 Series ...

Страница 2: ... following safety precautions before use Hazards that can occur from incorrect handling are classified by the symbols below Warning Caution Notice Indicate a potentially hazardous situation which if not avoided could result in death or serious injury Indicate a potentially hazardous situation which if not avoided could result in minor or moderate injury It could also be used to alert against unsafe...

Страница 3: ...ulfidizing gas or acidic alkaline chemical sprays are present These types of substances may damage internal parts cause device performance to be reduced and cause electrical shock Do not install the device in a bathroom kitchen or any room where steam could form Condensation may develop and cause electrical shock and or the device to malfunction Do not install the device in a location where there i...

Страница 4: ...m x 80mm x 24mm 3 94 x 3 15 x 0 94 inch Power Supply DC 12 24V Network F1 F2 Control Board Network AC Units Up to 64 Indoor units controlled as a group Compatibility SAMSUNG DVM CAC FJM RAC W x H x D Model name CL MC0301C CL MC0308C CL MC0316C CL MC0332C CL MC0364C of indoor unit to control monitor 1 8 16 32 64 4 System Configuration before installing Modbus Interface Module 4 1 Dip Switch Settings...

Страница 5: ...r unit control board for communication between SASMUNG indoor unit and Cyclogic Modbus Interface Module 3 Connect the CL MC03 cable to the terminals V1 V2 on the indoor unit control board for supplying power 4 Connect the CL MC03 cable to the 3rd party controller 4 2 Modbus Slave Address Setting with Rotary Switch RSW1 Ten RSW2 One RSW1 10 digit RSW2 one digit Initial settings Modbus Address can b...

Страница 6: ...n Instructions Oct 2016 2016 Cyclogic Inc Document Rev 1 Modbus Interface Module 5 2 Connection Diagram F1 F2 Outdoor Unit MODBUS INT Case 1 DVM CAC Case 2 RAC MODBUS INT Outdoor Unit F1 F2 Master Modbus Controller Master Modbus Controller F1 F2 Outdoor Unit MODBUS INT RSW1 Ten RSW2 One RSW1 Ten RSW2 One DIP SW2 OFF DIP SW2 ON DIP SW2 ON ...

Страница 7: ...ad Holding Registers and Preset Single Register Modbus RTU Slave 500m 0 to 63 indoor units 19600 Even 1 Register Type Access Function Preset Single Register Write Controls and Command Registers Holding Register Read Readback and Monitoring Registers All analogue and digital values are accessed through these registers All register values are 2 byte 16bit values Function Code hex code Function Name ...

Страница 8: ... R 3 FAN R 4 HEAT R 11 AUTO COOL R 12 AUTO DRY R 13 AUTO FAN R 14 AUTO HEAT R 40005 40025 41265 2 SET TEMPERATURE SET TEMP Data 10 R 40006 40026 41266 2 ROOM TEMPERATURE ROOM TEMP Data 10 R 40009 40029 41269 2 IDU FAN SPEED CONTROL 0 AUTOMATIC R 1 LOW R 2 MIDDLE R 3 HIGH R 4 TURBO R 40010 40030 41270 2 IDU DECO PANEL LOUVER SWING 0 SWING OFF R 1 SWING ON UPPER LOWER LOUVER R 2 SWING ON RIGHT LEFT ...

Страница 9: ...0 AUTO W 1 COOLING W DRY DEHUMIDIFICATION W 3 FAN W 4 HEAT W 11 AUTO COOL W 12 AUTO DRY W 13 AUTO FAN W 14 AUTO HEAT W SET TEMP Data 10 W 40009 40029 41269 2 IDU FAN SPEED CONTROL 0 AUTOMATIC W 1 LOW W 2 MIDDLE W 3 HIGH W 4 TURBO W 2 IDU DECO PANEL LOUVER SWING 0 SWING OFF W 1 SWING ON UPPER LOWER LOUVER W 2 SWING ON RIGHT LEFT LOUVER W 3 SWING ON UPPER LOWER RIGHT LEFT LOUVER W 40011 40031 41271 ...

Отзывы: