Shenzhen Zhiyong Electronics Co., Ltd

 

 

vibration or strike during operation.   

 

CPL2000 is neither waterproof nor dustproof. Please do not use it in dusty or wet environment.   

 

The upper and lower touching surface of the sensor head is created by accurate grinding process. 

Please try not to damage it or the function will be badly affected.   

 

 

 

 

The current probe has an inner square shape 9V battery. CPL2000 is highly power-consuming so 

please use the alkaline battery that can last long. 

 

Comparatively large test error could occur when the power supply is low. When the battery voltage 

is lower than 6.5V, the machine will notify the users by a low voltage alarm. Please change the 

battery ASAP to ensure the accuracy of testing.   

 

        CPL2000 Brief description

 

 

 

Type 

Max Current 

rms

 

Peak Value 

Current 

Bandwidth 

(-3dB) 

Range 

Selection 

Current 

Transfer 

Ratio 

CPL2000 

2000A 

3000Apk 

10kHz 

2000A 

1mV/A 

200A 

10mV/A 

 

 

 

 

 

 

 

 

Note 

CYBERTEK

Содержание CPL2000

Страница 1: ...Shenzhen Zhiyong Electronics Co Ltd www cybertek cn AC DC Low Frequency Current Probe CPL2000 2000A 10kHz Shenzhen Zhiyong Electronics Co Ltd CYBERTEK...

Страница 2: ...ut voltage surpassing the safety range if the basic insulation of the test terminal does not meet the requirement Please refer to the matters need attention about electronic safety Electric shock coul...

Страница 3: ...has an inner square shape 9V battery CPL2000 is highly power consuming so please use the alkaline battery that can last long Comparatively large test error could occur when the power supply is low Wh...

Страница 4: ...eface 1 CPL2000 Brief Description 2 Summary 4 Probe Parts Description 4 Electronics Specification 5 Operating Method 5 Mechanic Specification 6 Environmental Specification 6 Maintenance 6 Treatment wh...

Страница 5: ...s it to connect with oscilloscope and other devices including multi meter by BNC to Double Banana plug CPL2000 is usually used in fields including power frequency measurement motor drive and power sup...

Страница 6: ...Peak value current 300Apk 3000Apk Range Sensitivity 10mV A 1mV A Typical Accuracy DC 45Hz 66Hz 2 rdg 5mV 2 rdg 1mV Bandwidth 3dB DC 10kHz Operating voltage CATII 600V Typical battery type and service...

Страница 7: ...t Properly set the vertical sensitivity of the oscilloscope to generate stable wave form When oscilloscope is set DC CM user can observe both DC and AC component but if there s only AC CM only AC comp...

Страница 8: ...tery voltage lower than 6 5V Change the battery Amplitude low in all frequency range The input resistance of other testing device is 50 Please set the input resistance over 1M 9 Packing List PACKING L...

Отзывы: