TECHNICAL SPECIFICATIONS

Model

ST425

ST625U

ST900U

Capacity

425VA / 260W

625VA / 360W

900VA / 500W

Nominal Input Voltage

120 Vac

Input Frequency

50/60 Hz ± 3 Hz

On-Battery Output Voltage

120Vac ± 5%

On-Battery Output Frequency

50Hz/60Hz ± 1% (auto-sensing)

Max. Load for UPS Outlets

425VA / 260W

625VA / 360W

900VA / 500W

Max. Load for Full-Time Surge 

Protection outlets

7 Amps

12 Amps

12 Amps

On-Battery Output Wave Form

Simulated Sine Wave

Operating Temperature

+ 32°F to 104°F / 0°C to 40°C

Operating Relative Humidity

0 to 95% non-condensing

Size (W x H x D)

8.3” x 4.5” x 3.2”

210 x 115 x 81 mm

9.8” x 5.8” x 3.2”

250 x 147 x 82 mm

12.2” x 7” x 3.1”

310 x 178 x 80 mm

Net Weight (lbs / kg)

3.79 lbs / 1.72 kg

6.48 lbs / 2.94 kg

8.70 lbs / 3.95 kg

Typical Battery Recharge Time

8 hours typical from total discharge

Typical Battery Life

3 to 6 years, depending on number of discharge/recharge cycles

Recommended Battery

Sealed Maintenance Free Lead Acid Battery

Safety Approvals

UL1778(UPS), cUL CSA C22.2 No. 107.3-05, FCC/DoC Class B

Содержание ST425

Страница 1: ...UPS SERIES ST425 ST625U ST900U USER MANUAL FEATURES 1 Power On Switch 2 Power On Indicator green 3 Battery and Surge Protected Outlets 4 Full Time Surge Protection Outlets 5 Circuit Breaker 6 USB Port...

Страница 2: ...ire connect only to a circuit provided with 20 amperes maximum branch circuit over current protec tion in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room...

Страница 3: ...surge protection outlets DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical device into the Battery and Surge Protected Outlets The power demand...

Страница 4: ...as several battery powered and surge protected outlets to ensure tem porary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space hea...

Страница 5: ...ms com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support The frequency is beyond 47 63Hz Turn the UPS off Make sure the frequen cy range is within 47 63Hz Or you c...

Страница 6: ...Form Simulated Sine Wave Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative Humidity 0 to 95 non condensing Size W x H x D 8 3 x 4 5 x 3 2 210 x 115 x 81 mm 9 8 x 5 8 x 3 2 250 x 147...

Страница 7: ...ca gov This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any inter...

Отзывы: