CyberPower ST425 Скачать руководство пользователя страница 4

1.  

Power On Switch

  To turn the UPS on, press the power button 

for approximately 2 seconds - you will hear 

a constant tone (1 second) - and release 

after a short beep.

  To turn the UPS off, press the power button 

for approximately 2 seconds - you will hear 

a constant tone (1 second) - and release 

after two short beeps.

  Alarm setting: The audible alarm can be 

turned OFF or ON by quickly pressing the 

POWER button twice. The default setting 

is for the Alarm On. To turn the Alarm Off, 

quickly press the power button twice. You 

will hear two short beeps when the Alarm 

is turned off. To turn the Alarm back ON, 

quickly press the power button twice. You 

will hear a single short beep when the 

Alarm is turned on.

  *When the Alarm is turned off, there will 

be no audible notification when the UPS 

reaches a low battery state.

2.  

Power On Indicator (green)

  This LED is illuminated when the utility 

power is normal and the UPS outlets are 

providing power, free of surges and spikes. 

3.  

Battery and Surge Protected Outlets

  The unit has several battery powered and 

surge protected outlets to ensure tem-

porary uninterrupted operation of your 

equipment during a power failure. 

(DO 

NOT plug a laser printer, paper shredder, 

copier, space heater, vacuum cleaner, sump 

pump, or other large electrical device into 

the “Battery and Surge Protected Outlets.” 

The power demands of these devices will 

overload and possibly damage the unit.)

4.  

Full-Time Surge Protection Outlets

  The unit has several surge suppression  

outlets.

5.  

Circuit Breaker

  Located on the side of the UPS, the circuit 

breaker serves to provide overload and 

fault protection. 

6.  

USB Port to PC (except for ST425)

  The port allows connection and communi-

cation between the USB port on the com-

puter and the UPS unit. The UPS communi-

cates its status to the PowerPanel® Personal 

software.

7.  

USB Charging ports (except for ST425)

  The USB charging ports provide 5V 2.1A 

power output.

8.  

Widely-Spaced Outlets

  The UPS unit has four widely-spaced out-

lets, so AC power adapters can be plugged 

into the UPS without overlapping or block-

ing adjacent outlets.

BASIC OPERATION

SYSTEM FUNCTION BLOCK DIAGRAM

Input

Output

Battery Mode

Normal Mode

EMI

Filter

Surge

Suppressor

Inverter

Charger

AC / DC

Battery

Содержание ST425

Страница 1: ...UPS SERIES ST425 ST625U ST900U USER MANUAL FEATURES 1 Power On Switch 2 Power On Indicator green 3 Battery and Surge Protected Outlets 4 Full Time Surge Protection Outlets 5 Circuit Breaker 6 USB Port...

Страница 2: ...ire connect only to a circuit provided with 20 amperes maximum branch circuit over current protec tion in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room...

Страница 3: ...surge protection outlets DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical device into the Battery and Surge Protected Outlets The power demand...

Страница 4: ...as several battery powered and surge protected outlets to ensure tem porary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space hea...

Страница 5: ...ms com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support The frequency is beyond 47 63Hz Turn the UPS off Make sure the frequen cy range is within 47 63Hz Or you c...

Страница 6: ...Form Simulated Sine Wave Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative Humidity 0 to 95 non condensing Size W x H x D 8 3 x 4 5 x 3 2 210 x 115 x 81 mm 9 8 x 5 8 x 3 2 250 x 147...

Страница 7: ...ca gov This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any inter...

Отзывы: