INSTALLING YOUR UPS SYSTEM

UNPACKING

Inspect the UPS upon receipt.  

The box should contain the following:
(a) UPS unit  

(b) User’s manual  

(c) USB device cable (except for ST425) 

DETERMINE THE POWER  

REQUIREMENTS OF YOUR EQUIPMENT

1.   Ensure that the equipment plugged 

into the outlet does not exceed the UPS 

unit’s rated capacity (425VA/260W for 

ST425, 625VA/360W for ST625U, and 

900VA/500W ST900U). If the rated  

capacities of the unit are exceeded, an 

overload condition may occur and cause 

the UPS unit to shut down or the circuit 

breaker to trip.

2.  There are many factors that can affect  

the amount of power that your electronic 

equipment will require. For optimal system  

performance keep the load below 80% of 

the unit’s rated capacity.

HARDWARE INSTALLATION GUIDE

 

1.   Your new UPS may be used immediately 

upon receipt. However, after receiving a 

new UPS, to ensure the battery’s maximum 

charge capacity, it is recommended that 

you charge the battery for at least 8 hours. 

Your UPS is equipped with an auto-charge 

feature. When the UPS is plugged into an 

AC outlet, the battery will automatically 

charge whether the UPS is turned on or 

turned off.

2.  With the UPS unit turned off and unplugged, 

connect your equipment requiring battery 

backup into the battery power supplied 

outlets. Plug the other peripheral equip-

ment (printer, scanner, speakers) into the 

full-time surge protection outlets.  

DO NOT plug a laser printer, paper  

shredder, copier, space heater, vacuum, 

sump pump or other large electrical  

device into the “Battery and Surge  

Protected Outlets”. The power demands 

of these devices will overload and possi-

bly damage the unit.

3.  Plug the UPS into a 2-pole, 3-wire ground-

ed receptacle (wall outlet). Make sure the 

wall branch outlet is protected by a fuse or 

circuit breaker and does not service equip-

ment with large electrical demands (e.g. 

air conditioner, refrigerator, copier, etc…). 

The warranty prohibits the use of extension 

cords, outlet strips, and surge strips.

4.  Press the power switch to turn the unit on. 

The Power On indicator light will illuminate 

green and the unit will “beep” twice.

5.  If an overload is detected, an audible alarm 

will sound and the unit will emit one long 

beep. To correct this, turn the UPS off and 

unplug at least one piece of equipment 

from the battery power supplied outlets. 

Make sure the circuit breaker is depressed 

and then turn the UPS on.

6.  To maintain optimal battery charge, leave the 

UPS plugged into an AC outlet at all times.

7.   To store the UPS for an extended period 

of time, cover it and store with the battery 

fully charged. While in storage, recharge 

the battery every three months to ensure 

optimal battery life.

8.  Ensure the wall outlet and UPS are located 

near the equipment being attached for 

proper accessibility.

9.  Lay the UPS horizontally or use the key-

hole mounting slots to affix the UPS to 

the wall in the proper orientation. DO NOT 

stand the UPS up vertically. 

 

Содержание ST425

Страница 1: ...UPS SERIES ST425 ST625U ST900U USER MANUAL FEATURES 1 Power On Switch 2 Power On Indicator green 3 Battery and Surge Protected Outlets 4 Full Time Surge Protection Outlets 5 Circuit Breaker 6 USB Port...

Страница 2: ...ire connect only to a circuit provided with 20 amperes maximum branch circuit over current protec tion in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room...

Страница 3: ...surge protection outlets DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical device into the Battery and Surge Protected Outlets The power demand...

Страница 4: ...as several battery powered and surge protected outlets to ensure tem porary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space hea...

Страница 5: ...ms com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support The frequency is beyond 47 63Hz Turn the UPS off Make sure the frequen cy range is within 47 63Hz Or you c...

Страница 6: ...Form Simulated Sine Wave Operating Temperature 32 F to 104 F 0 C to 40 C Operating Relative Humidity 0 to 95 non condensing Size W x H x D 8 3 x 4 5 x 3 2 210 x 115 x 81 mm 9 8 x 5 8 x 3 2 250 x 147...

Страница 7: ...ca gov This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any inter...

Отзывы: