Technical specifications 

Model 

PR1500 

PR2200 

Capacity(VA)/(Watt) 1500VA/1000W 

2200VA/1500W 

Input 

Voltage Range 

85-150Vac 

Frequency Range 

47-63Hz 

Output 

On battery Output Voltage 

Pure sine wave at /-7% 

Transfer time(Typical) 

60Hz 

Overload protection 

4ms 

Internet Ready 

On Utility: Circuit Breaker; On Battery: Internal Current Limiting 

Surge Protection and Filtering 

Lightning/Surge Protection 

Yes 

Internet Ready(DSL / Phone / 

FAX / Modem Protection) 

RJ11/RJ45(One In/One Out) 

Physical 

Toatal # of UPS Receptacles   

Maximum Dimensions (in) 

2U Rack *2   

17.1"

 

x

 

15.3"

 

x

 

3.5"

 

Weight (lbs) 

58 

58 

Battery 

Sealed Maintenance Free Lead 

Acid Battery 

12Vdc 7AHx4 

12Vdc 9AHx4 

Typical Recharge Time 

8 Hours 

Warning Diagnostics 

Indicators 

Power on, using battery, AVR, wiring fault, load level, battery level 

Audible Alarms 

On Battery, Low Battery, Overload 

Environmental 

Operating Temperature 

32 °F to 104°F / 0°C to 40 °C 

Operating Relative Humidity 

0 to 95% NON-CONDENSING 

Communication 

Power Panel (Plus) Software 

Windows 98/ME/NT/2000/XP, MAC OS 10.0 or later. 

Management 

Self-Test Manual 

Self-Test 

Auto-Charger /Auto-Restart 

Yes 

USB Yes 

Содержание PR2200

Страница 1: ...User s Manual Professional Rack Mount UPS PR1500 PR2200 K01 1500S0A 04...

Страница 2: ...MITED WARRANTY 12 CONFORMANCE APPROVALS 15 Thank you for purchasing a CyberPower Systems Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow...

Страница 3: ...ttery No user serviceable parts inside except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a co...

Страница 4: ...ords If used the extension cord must be rated for 15 Amps 6 Depress the power switch to turn the unit on The power on indicator light will illuminate If an overload is detected an audible alarm will s...

Страница 5: ...is supplying power to the battery power supplied outlets AVR Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode When the LED is illuminated continuously it ind...

Страница 6: ...f connected equipment during a power failure Individual Backup Power for Critical Load The UPS provides two battery powered surge protected and AVR outlets for the most critical connected equipment an...

Страница 7: ...h PowerPanel software installed is unable to exhibit any control over the UPS When there is a power failure the Primary computer will start to shutdown after a user controlled delay Once the Primary c...

Страница 8: ...local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can presen...

Страница 9: ...en remove the cover Disconnect the black and red cable Remove the four retaining screws Pull the battery pack out from the unit Slide a new battery pack into the unit Assemble the screws cover cable a...

Страница 10: ...flash On off Set Long beeps Overload Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and restart the UPS Off Off Off On Up Long beep...

Страница 11: ...seconds and then turn the UPS on The unit is not connected to an AC outlet The unit must be connected to a 110 120V 50 60Hz outlet The battery is worn out Contact CyberPower about replacement batteri...

Страница 12: ...RJ45 One In One Out Physical Toatal of UPS Receptacles 7 Maximum Dimensions in 2U Rack 2 17 1 x 15 3 x 3 5 Weight lbs 58 58 Battery Sealed Maintenance Free Lead Acid Battery 12Vdc 7AHx4 12Vdc 9AHx4 T...

Страница 13: ...ment that was connected to the Product and damaged because of the failure of the Product What Is the Period of Coverage This warranty covers the Product for three years and connected equipment for as...

Страница 14: ...eplaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or...

Страница 15: ...e Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT...

Страница 16: ...and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this...

Страница 17: ...16...

Страница 18: ...erpowersystems com E mail sales cyberpowersystems com CyberPower Europe CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 Website http e...

Отзывы: