Definitions for led indicators
Power
On
Wiring
Fault
AVR
Using
Battery
Circuit
Breaker
Alarm
Condition
On Off Off Off Set Off
Normal
On
Off
Flash
Off
Set
Off
AVR-
Max. boost 15% of input
voltage for output regulation while
input voltage is from 8% to 30%
under nominal.
On
Off
On
Off
Set
Off
AVR-
Max. buck 15% of input
voltage for output regulation while
input voltage is from 8% to 26%
over nominal.
Off
On/Off
Off
On
Set
Two
beeps
Utility Failure-
The UPS is
providing battery power to the
Battery-Power Supplied outlets.
Off
Off
On
On
Set
Rapid
beeps
Utility Failure-
The UPS is
providing battery
power.Rapid beeps indicate the
battery will run out of charge
within a few minutes.
On/off
On/off/
On/off
flash
On/off
Set
Long
beeps
Overload-
Turn the UPS off and
unplug at least one piece of
equipment from the UPS. Wait 5
seconds, reset the circuit breaker
and restart the UPS.
Off
Off
Off
On
Up
Long
beep
Overload-
Turn the UPS off and
unplug at least one piece of
equipment from the UPS. Wait 5
seconds, reset the circuit breaker
and restart the UPS.
On
On/Of
On/Off
Flash
Off
Set
On
Weak Battery-
Recharge the
battery for at least 8 hours. If
Check Battery
is illuminated,
contact CyberPower Systems
for battery replacement
information.
On
On/Of
On/Off
Flash
Off
Set
On
Weak Battery-
Recharge the
battery for at least 8 hours. If
Check Battery
is illuminated,
contact CyberPower Systems
for battery replacement
information.
On
On/Of
On/Off
Flash
Off
Set
On
Weak Battery-
Recharge the
battery for at least 8 hours. If
Check Battery
is illuminated,
contact CyberPower Systems for
battery replacement information.