  (SAVE THESE INSTRUCTIONS) 

 

This manual contains important safety instructions. Please read and follow all instructions carefully during 
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or 
operate your UPS. 
 

CAUTION!   

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor 

area  free  of  conductive  contaminants.    (Please  see  specifications  for  acceptable  temperature  and  humidity 
range). 
 

CAUTION!   

To reduce the risk of electric shock, do not remove the cover except to service the battery. Ensure 

the input power is removed before servicing the batteries. There are no user serviceable parts inside except for 
the battery. 
 

CAUTION!   

Hazardous  live  parts  inside  can  be  energized  by  the  battery  even  when  the  AC  input  power  is 

disconnected. 
 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do 

not plug into an outlet that is not grounded.    If you need to de-energize this equipment, turn off and unplug the 
unit. 
 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing 

the battery or installing a computer component. 
 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  (OR1500PFCRT2U  and 

OR2200PFCRT2U)  or  30  (OR2200PFCRT2Ua)  amperes  maximum  branch  circuit  over  current  protection  in 
accordance with the National Electric Code, ANSI/NFPA 70. 
 

CAUTION!

    The UPS is suitable for use in a computer room as defined in the Standard for the Protection of 

Electronic Computer/Data Processing Equipment, ANSI/NFPA 75. 
 

DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

CyberPower  Systems  does  not  sell 

products  for  life  support  or  medical  applications.   

DO  NOT

  use  in  any  circumstance  that  would  affect  the 

operation and safety of life support equipment, medical applications, or patient care. 
 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or 

near an aquarium.

   

Condensation from the aquarium can cause the unit to short out.

 

 

 

 

INTRODUCTION 

Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed 
power protection, operation and performance during the lifetime of the product. 
 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 
(a) UPS unit x 1 (b) User’s manual x 1 (c) Rack mount brackets x 2 (d) Vertical stands x 2 (e) Telephone cable x 
1 (f) Emergency Power Off cable (gray) x 1 (g) PowerPanel

®

 Business Edition software CD x 1 (h) Serial cable 

x 1 (i) USB A+B type cable x 1 (j) Warranty registration card x 1 
 
 
 

IMPORTANT SAFETY INSTRUCTIONS   

INSTALLING YOUR UPS SYSTEM 

Содержание OR1500PFCRT2U

Страница 1: ...User s Manual OR1500PFCRT2U OR2200PFCRT2U OR2200PFCRT2Ua K01 0000206 00 ...

Страница 2: ...f fire connect only to a circuit provided with 20 OR1500PFCRT2U and OR2200PFCRT2U or 30 OR2200PFCRT2Ua amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION The UPS is suitable for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 DO NOT USE FOR MEDIC...

Страница 3: ...nt plugged into the outlet does not exceed the UPS unit s rated capacity 1500VA 900W for OR1500PFCRT2U 2000VA 1320W for OR2200PFCRT2U and 2200VA 1320W for OR2200PFCRT2Ua If the rated capacities of the unit are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your computer sy...

Страница 4: ...three months to ensure battery life 8 To use PowerPanel Business Edition software connect the serial cable to the serial port or the USB port on both the UPS and the computer These OR units include one serial port and one USB port to allow connection and communication between the UPS and computers The primary computer with PowerPanel Business Edition installed is the computer that you will use to ...

Страница 5: ...circuit breakers provide input optimal overload protection 9 USB Port The USB port allows connection and communication between the USB port on the computer and the UPS unit 10 Communication Protection Ports Communication protection ports will protect any standard modem fax telephone line network or Ethernet connection RJ11 RJ45 11 Wiring Fault Indicator red This LED indicator will illuminate to wa...

Страница 6: ...nergy conducted through these materials could cause severe burns 3 CAUTION Do not dispose of batteries in a fire The batteries may explode 4 CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS BATTERY REPLACEMENT PROC...

Страница 7: ...until the battery reaches low capacity 8 OVER LOAD icon This icon appears and an alarm sounds to indicate the battery supplied outlets are overloaded To clear the overload unplug some of your equipment from the battery supplied outlets until the icon turns off and the alarm stops 9 FAULT icon This icon appears if there is a problem with the UPS Contact CyberPower Systems at tech cyberpowersystems ...

Страница 8: ...Medium 88 139Vac This is the default setting High 90 136Vac This unit is most sensitive to voltage fluctuations LCD Always On On The LCD is always on whether or not the LCD button is pressed Off In Line Mode if the LCD display button is not touched for 1 minute the UPS will enter Sleeping Mode The LCD will not appear until the display button is pressed In Battery Mode the LCD is always on Self Tes...

Страница 9: ...cyberpowersystems com The UPS will not turn on The on off switch is designed to prevent damage from rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The unit is not connected to an AC outlet The unit must be connected to a 110 120V 60Hz outlet The battery is worn out Contact CyberPower Systems about replacement batteries at tech cyberpowersystems com Mechanic...

Страница 10: ...ating Relative Humidity 0 to 90 non condensing Size L x W x H 433 x 388 x 88 mm 2U Rack 17 x 15 3 x 3 5 Net Weight 55 1lbs 25kg 59 3lbs 26 9kg 60lbs 27 2kg Battery Type 12V 7Ah RBP433 CyberPower 12V 8 5Ah RBP435 CyberPower 12V 8 5Ah RBP435 CyberPower Typical Battery Recharge Time 8 hours from total discharge Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recomme...

Страница 11: ...nty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions It also covers equipment that was connected to the Product and damaged because of the failure of the Product What is the Period of Coverage This warranty covers the Product for three years and connected equipment for as long as you own the Product Who Is Covered This warranty only cov...

Страница 12: ... improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life support devices etc What are the Limitations The sole and exclusive remedies of the Initial Customer are those provided by this Warranty 1 This Warranty does not apply unless the Product and the equipment that was connected to it were co...

Страница 13: ...ct is not for use in high risk activities or with aquariums The Product is not designed or intended for use in hazardous environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device colle...

Отзывы: