CyberPower OR1500PFCRT2U Скачать руководство пользователя страница 12

12 

cost estimate for the damage to the Connected Equipment, and all claim forms that CyberPower provides 
to you. Show the Claim Number on the shipping label or include it with the product. 

You must prepay all 

shipping costs, you are responsible for packaging and shipment, and you must pay the cost of the 
repair estimate.

 

 

How Long Do I Have To Make A Claim?

 

All claims must be made within ten days of the occurrence. 
 

What Will We Do To Correct Problems? 

CyberPower will inspect and examine the Product. 
If  the  Product  is  defective  in  material  or  workmanship,  CyberPower  will  repair  or  replace  it  at  CyberPower's 
expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a 
reasonable  time,  CyberPower  will  refund  to  you  the  full  purchase  price  you  paid  for  the  Product  (purchase 
receipt showing price paid is required). 
If it appears that our Product failed to protect any equipment plugged into it, we will also send you forms for 
making your claim for the connected equipment.    We will repair or replace the equipment that was damaged 
because  of the  failure  of our Product or pay  you the  fair market value (NOT REPLACEMENT COST) of the 
equipment at of the time of the damage.    We will use Orion Blue Book, or another a third-party valuation guide, 
or eBay, craigslist, or other source to establish that amount.    Our maximum liability is limited to $200,000 for 
the OR1500PFCRT2U, $250,000 for the OR2200PFCRT2U and OR2200PFCRT2Ua. 

 

Who Pays For Shipping? 

We pay when we send items to you; you pay when you send items to us. 
 

What isn’t covered by the warranty? 

1.  This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of 

the  Product  or any data  that is lost as a result of the failure  or  the restoration of data  or records,  or the 
reinstallation of software.

 

2.  This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental 

limits of the Product or the equipment connected to it, nor for damage while in transit or in storage, nor if 
there has been improper operation or maintenance, or use with items not designed or intended for use with 
the Product, such as laser printers, appliances, aquariums, medical or life support devices, etc.

 

 

What are the Limitations? 

The sole and exclusive remedies of the Initial Customer are those provided by this Warranty. 
1.  This  Warranty  does  not  apply  unless  the  Product  and  the  equipment  that  was  connected  to  it  were 

connected to properly wired and grounded outlets (including compliance with electrical and safety codes of 
the most current electrical code), without the use of any adapters or other connectors. 

2.  The Product must have been plugged directly into the power source and the equipment connected to the 

Product must be directly connected to the Product and not “daisy-chained” together in serial fashion with 
any extension cords, another Product or device similar to the Product, surge suppressor, or power tap. Any 
such installation voids the Limited Warranty. 

3.  The  Product  and  equipment  connected  to  it  must  have  been  used  properly  in  a  suitable  and  proper 

environment  and  in  conformance  with  any  license,  instruction  manual,  or  warnings  provided  with  the 
Product and the equipment connected to it. 

4.  The Product must have been used at all times within the limitations on the Product’s VA capacity. 

 

The Product was designed to eliminate disrupting and damaging effects of momentary (less than 1ms) voltage 
spikes  or  impulses  from  lightning  or  other  power  transients.    If  it  can  be  shown  that  a  voltage  spike  lasting 
longer than 1ms has occurred, the occurrence will be deemed outside the rated capabilities of the Product and 
the Limited Warranty is void. CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of 
the Following: 
1.  Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of 

software. 

2.  Damage  from  causes  other  than  AC  Power  Line  Transients,  spikes,  or  surges  on  properly  installed, 

grounded and code-compliant 120 volt power lines in the United States and Canada; transients, surges or 
spikes on standard telephone land lines, PBX telephone equipment lines or Base 10T Ethernet lines, when 
properly installed and connected. (This exclusion applies, for example, to fluctuations in data transmission 

Содержание OR1500PFCRT2U

Страница 1: ...User s Manual OR1500PFCRT2U OR2200PFCRT2U OR2200PFCRT2Ua K01 0000206 00 ...

Страница 2: ...f fire connect only to a circuit provided with 20 OR1500PFCRT2U and OR2200PFCRT2U or 30 OR2200PFCRT2Ua amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION The UPS is suitable for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 DO NOT USE FOR MEDIC...

Страница 3: ...nt plugged into the outlet does not exceed the UPS unit s rated capacity 1500VA 900W for OR1500PFCRT2U 2000VA 1320W for OR2200PFCRT2U and 2200VA 1320W for OR2200PFCRT2Ua If the rated capacities of the unit are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your computer sy...

Страница 4: ...three months to ensure battery life 8 To use PowerPanel Business Edition software connect the serial cable to the serial port or the USB port on both the UPS and the computer These OR units include one serial port and one USB port to allow connection and communication between the UPS and computers The primary computer with PowerPanel Business Edition installed is the computer that you will use to ...

Страница 5: ...circuit breakers provide input optimal overload protection 9 USB Port The USB port allows connection and communication between the USB port on the computer and the UPS unit 10 Communication Protection Ports Communication protection ports will protect any standard modem fax telephone line network or Ethernet connection RJ11 RJ45 11 Wiring Fault Indicator red This LED indicator will illuminate to wa...

Страница 6: ...nergy conducted through these materials could cause severe burns 3 CAUTION Do not dispose of batteries in a fire The batteries may explode 4 CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS BATTERY REPLACEMENT PROC...

Страница 7: ...until the battery reaches low capacity 8 OVER LOAD icon This icon appears and an alarm sounds to indicate the battery supplied outlets are overloaded To clear the overload unplug some of your equipment from the battery supplied outlets until the icon turns off and the alarm stops 9 FAULT icon This icon appears if there is a problem with the UPS Contact CyberPower Systems at tech cyberpowersystems ...

Страница 8: ...Medium 88 139Vac This is the default setting High 90 136Vac This unit is most sensitive to voltage fluctuations LCD Always On On The LCD is always on whether or not the LCD button is pressed Off In Line Mode if the LCD display button is not touched for 1 minute the UPS will enter Sleeping Mode The LCD will not appear until the display button is pressed In Battery Mode the LCD is always on Self Tes...

Страница 9: ...cyberpowersystems com The UPS will not turn on The on off switch is designed to prevent damage from rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The unit is not connected to an AC outlet The unit must be connected to a 110 120V 60Hz outlet The battery is worn out Contact CyberPower Systems about replacement batteries at tech cyberpowersystems com Mechanic...

Страница 10: ...ating Relative Humidity 0 to 90 non condensing Size L x W x H 433 x 388 x 88 mm 2U Rack 17 x 15 3 x 3 5 Net Weight 55 1lbs 25kg 59 3lbs 26 9kg 60lbs 27 2kg Battery Type 12V 7Ah RBP433 CyberPower 12V 8 5Ah RBP435 CyberPower 12V 8 5Ah RBP435 CyberPower Typical Battery Recharge Time 8 hours from total discharge Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recomme...

Страница 11: ...nty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions It also covers equipment that was connected to the Product and damaged because of the failure of the Product What is the Period of Coverage This warranty covers the Product for three years and connected equipment for as long as you own the Product Who Is Covered This warranty only cov...

Страница 12: ... improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life support devices etc What are the Limitations The sole and exclusive remedies of the Initial Customer are those provided by this Warranty 1 This Warranty does not apply unless the Product and the equipment that was connected to it were co...

Страница 13: ...ct is not for use in high risk activities or with aquariums The Product is not designed or intended for use in hazardous environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device colle...

Отзывы: