TECHNICAL SPECIFICATIONS

Model

OR1500LCDRTXL2U

OR2200LCDRTXL2U

Capacity

1500VA / 1125W

2190VA / 1650W

Input Voltage or Utility

90V to 140V

Input Frequency

47 Hz ± 63 Hz (Auto-sensing)

On-Battery Output Voltage

120Vac ± 5%

Transfer Time

4 ms Typical

Max Load for UPS Outlets  

(8 Outlets)

1500VA / 1125W

2190VA / 1650W

On-Battery Output  

Wave Form

Simulated Sine Wave Form

Operating Temperature

+ 32°F to 104° F / 0° C to 40° C

Operating Relative Humidity

0 to 90% non-condensing

Size (L x W x H)

433 x 478 x 88 mm (2U Rack) / 17 x 18.8 x 3.5 in.

Net Weight

59.5 lbs. / 27 kg

66.1 lbs. / 30 kg

Battery Type

CyberPower / RBP834

CyberPower / RBP844

Typical Battery  

Recharge Time

8 hours

Typical Battery Life

3 to 6 years, depending on number of discharge/recharge cycles

Recommended Battery

Sealed Maintenance Free Lead Acid Battery

Safety Approvals

UL1778, CSA C22.2 No 107.3, FCC/DoC Class B

SYSTEM FUNCTION BLOCK DIAGRAM

Input

Output

Battery Mode

Normal Mode

EMI

Filter

Surge

Suppressor

Inverter

Charger

AC / DC

Battery

AVR

Содержание OR1500LCDRTXL2U

Страница 1: ...e 3 LCD Module Display 4 LCD Function Selection Switch 5 8 Full Time Battery Powered and Surge Protected Outlets 6 AC Power Cord 7 Output Circuit Breaker 8 Input Circuit Breaker 9 USB Port 10 Communication Protection Ports RJ45 11 Wiring Fault Indicator Red 12 Coax Cable DSS Surge Protection 13 Serial Port I Primary 14 Serial Port II Dry Contact 15 EPO Emergency Power Off Port 16 SNMP HTTP Network...

Страница 2: ...lling a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 CAUTION Do not dispose of batterie...

Страница 3: ...ses high utility power to a consistent and safe 110 120 volts If incoming utility voltage drops below 90 volts or exceeds 140 volts the units automatically switch to battery back up power DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the outlet does not exceed the UPS unit s rated capacity 1500VA 1125W for OR1500LCDRTXL2U 2190VA 1650W for OR2200LCDRTXL...

Страница 4: ...ttery power supplied outlets Make sure the circuit breaker is depressed and then turn the UPS on 6 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 7 To store the UPS for an extended period cover it and store with the battery fully charged While in storage recharge the battery every three months to ensure battery life 8 To use PowerPanel Business Edition soft...

Страница 5: ...0 Communication Protection Ports Communication protection ports will protect any standard modem fax telephone line network or Ethernet connection RJ11 RJ45 11 Wiring Fault Indicator red This LED indicator will illuminate to warn the user that a wiring problem exists such as bad ground missing ground or reversed wiring If this is illuminated disconnect all electrical equipments from the outlet and ...

Страница 6: ...hrough these materials could cause severe burns 3 CAUTION Do not dispose of batteries in a fire The batteries may explode 4 CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS REPLACING THE BATTERY BATTERY REPLACEMENT...

Страница 7: ...cond and the BATT CAPACITY meter shows one 20 capacity segment shaded to indicate the UPS s batteries are nearly out of power You should save files and turn off your equip ment immediately 6 AVR Automatic Voltage Regulation Icon This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power This is a normal automatic operation of your UPS and no act...

Страница 8: ...tive all icons are gray The USB Serial cable is not connected Connect the USB serial cable to the UPS unit and an open USB serial port on the back of the com puter You must use the cable that came with the unit The USB serial cable is connected to the wrong port Check the back of the computer for an additional USB serial port Move the cable to this port The unit is not providing battery power Shut...

Страница 9: ...F 0 C to 40 C Operating Relative Humidity 0 to 90 non condensing Size L x W x H 433 x 478 x 88 mm 2U Rack 17 x 18 8 x 3 5 in Net Weight 59 5 lbs 27 kg 66 1 lbs 30 kg Battery Type CyberPower RBP834 CyberPower RBP844 Typical Battery Recharge Time 8 hours Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Sa...

Страница 10: ...ur state This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of ...

Отзывы: