CyberPower OR1500LCDRTXL2U Скачать руководство пользователя страница 2

Thank you for purchasing a CyberPower product.  This UPS is designed to provide unsurpassed 

power protection, operation, and performance during the lifetime of the product. Please take a 

few minutes to register your product at: 

www.CyberPowerSystems.com/registration

.  

Registration certifies your product’s warranty, confirms your ownership in the event of a 

product loss or theft, and entitles you to free technical support. Register your product now to 

receive the benefits of CyberPower ownership.

CAUTION! 

 To prevent the risk of fire or  

electric shock, install in a temperature and 

humidity controlled indoor area free of  

conductive contaminants. (Please see  

specifications for acceptable temperature  

and humidity range). 

CAUTION!

 To reduce the risk of electric shock, 

do not remove the cover except to service the 

battery. Turn off and unplug the unit before

servicing the batteries. There are no user 

serviceable parts inside except for the battery.

CAUTION!

 Hazardous live parts inside can be 

energized by the battery even when the AC 

input power is disconnected.

CAUTION!

 The UPS must be connected to an 

AC power outlet with fuse or circuit breaker 

protection. Do not plug into an outlet that is 

not grounded. If you need to de-energize this 

equipment, turn off and unplug the unit.

CAUTION!

 To avoid electric shock, turn off the 

unit and unplug it from the AC power source 

before installing a computer component.

CAUTION!

 To reduce the risk of fire, connect 

only to a circuit provided with 20 amperes 

maximum branch circuit over current 

protection in accordance with the National 

Electric Code, ANSI/NFPA 70.

CAUTION!

 Not for use in a computer room 

as defined in the Standard for the Protection 

of Electronic Computer/Data Processing 

Equipment, ANSI/NFPA 75.

CAUTION!

 Do not dispose of batteries in a 

fire. The batteries may explode.

CAUTION!

 Do not open or mutilate batteries. 

Released electrolyte is harmful to the skin and 

eyes. It may be toxic.

DO NOT USE FOR MEDICAL  

OR LIFE SUPPORT EQUIPMENT!

  

CyberPower Systems does not sell products 

for life support or medical applications. DO 

NOT use in any circumstance that would 

affect operation and safety of life support 

equipment, any medical applications or 

patient care.

DO NOT USE WITH OR NEAR AQUARIUMS!

  

To reduce the risk of fire or electric shock, 

do not use with or near an aquarium. 

Condensation from the aquarium can cause 

the unit to short out.

DO NOT USE THE UPS  

ON ANY TRANSPORTATION!

  

To reduce the risk of fire or electric shock, do 

not use the unit on any transportation such 

as airplanes or ships. The effect of shock or 

vibration caused during transit and the damp 

environment can cause the unit to short out.

PRODUCT REGISTRATION

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions carefully 

during installation and operation of the unit. Read this manual thoroughly before attempting to 

unpack, install, or operate your UPS.

Содержание OR1500LCDRTXL2U

Страница 1: ...e 3 LCD Module Display 4 LCD Function Selection Switch 5 8 Full Time Battery Powered and Surge Protected Outlets 6 AC Power Cord 7 Output Circuit Breaker 8 Input Circuit Breaker 9 USB Port 10 Communication Protection Ports RJ45 11 Wiring Fault Indicator Red 12 Coax Cable DSS Surge Protection 13 Serial Port I Primary 14 Serial Port II Dry Contact 15 EPO Emergency Power Off Port 16 SNMP HTTP Network...

Страница 2: ...lling a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 CAUTION Do not dispose of batterie...

Страница 3: ...ses high utility power to a consistent and safe 110 120 volts If incoming utility voltage drops below 90 volts or exceeds 140 volts the units automatically switch to battery back up power DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the outlet does not exceed the UPS unit s rated capacity 1500VA 1125W for OR1500LCDRTXL2U 2190VA 1650W for OR2200LCDRTXL...

Страница 4: ...ttery power supplied outlets Make sure the circuit breaker is depressed and then turn the UPS on 6 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 7 To store the UPS for an extended period cover it and store with the battery fully charged While in storage recharge the battery every three months to ensure battery life 8 To use PowerPanel Business Edition soft...

Страница 5: ...0 Communication Protection Ports Communication protection ports will protect any standard modem fax telephone line network or Ethernet connection RJ11 RJ45 11 Wiring Fault Indicator red This LED indicator will illuminate to warn the user that a wiring problem exists such as bad ground missing ground or reversed wiring If this is illuminated disconnect all electrical equipments from the outlet and ...

Страница 6: ...hrough these materials could cause severe burns 3 CAUTION Do not dispose of batteries in a fire The batteries may explode 4 CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS REPLACING THE BATTERY BATTERY REPLACEMENT...

Страница 7: ...cond and the BATT CAPACITY meter shows one 20 capacity segment shaded to indicate the UPS s batteries are nearly out of power You should save files and turn off your equip ment immediately 6 AVR Automatic Voltage Regulation Icon This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power This is a normal automatic operation of your UPS and no act...

Страница 8: ...tive all icons are gray The USB Serial cable is not connected Connect the USB serial cable to the UPS unit and an open USB serial port on the back of the com puter You must use the cable that came with the unit The USB serial cable is connected to the wrong port Check the back of the computer for an additional USB serial port Move the cable to this port The unit is not providing battery power Shut...

Страница 9: ...F 0 C to 40 C Operating Relative Humidity 0 to 90 non condensing Size L x W x H 433 x 478 x 88 mm 2U Rack 17 x 18 8 x 3 5 in Net Weight 59 5 lbs 27 kg 66 1 lbs 30 kg Battery Type CyberPower RBP834 CyberPower RBP844 Typical Battery Recharge Time 8 hours Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Sa...

Страница 10: ...ur state This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of ...

Отзывы: