CyberPower MBP63A2 Скачать руководство пользователя страница 30

©2020 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners. 

25

LIMITED WARRANTY

Thank you for purchasing a CyberPower product. This manual contains important information 
regarding the safety, installation, operation, maintenance, and storage of this CyberPower MBP63A2 
("Product"). Failure to read this guide and follow all directions could result in injury and/or property 
damage. Carefully read all instructions before installing and using the Product and pay special 
attention to all CAUTION and WARNING statements. Misusing or incorrectly connecting the Product 
may damage the Product or any equipment connected to the Product ("Connected Equipment") or 
create hazardous conditions. Failure to follow these instructions will void the Product's Warranty. 
By using the Product you consent to be bound by and become a party to the terms and conditions 
of this Limited Warranty (together referred to as the “Warranty”). If you do not agree to the terms 
and conditions of this Warranty, you should return the Product for a full refund prior to using it.

Who is Providing this Warranty? 

Cyber Power Systems, (USA) Inc. (“CyberPower”) is the warrantor under this Warranty. Except 
as required by law, this Warranty only covers the original purchaser ("Initial Customer"). The 
Warranty may not be transferred to any third party and coverage ends if the Initial Customer sells 
or otherwise transfers the Product. To be covered the Initial Customer must still be the owner of the 
Product at the time of the failure that results in the claim made under this Warranty ("Occurrence").

TO THE FULLEST EXTENT PERMITTED BY LAW, CYBERPOWER SHALL HAVE NO LIABILITY 
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE, MULTIPLE, OR CONSEQUENTIAL 
DAMAGES OF ANY KIND, WHETHER FOR DAMAGE TO OR LOSS OF PROPERTY, FOR INJURY 
OR DAMAGE TO BUSINESS, BUSINESS INTERRUPTION, LOSS OF INFORMATION OR DATA, OR 
LOSS OF PROFITS, REVENUES OR GOODWILL. CYBERPOWER SHALL HAVE NO LIABILITY FOR 
PERSONAL INJURY UNDER THIS WARRANTY. THESE EXCLUSIONS APPLY REGARDLESS OF 
CAUSE, WHETHER ARISING UNDER BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE 
OR FAULT), STRICT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF 
SUCH. THE PREVAILING PARTY SHALL BE ENTITLED TO THEIR COSTS, DISBURSEMENTS 
AND REASONABLE ATTORNEY'S FEES AND FOR ANY CLAIM UNDER THE WARRANTY OR 
OTHERWISE ASSOCIATED WITH THE PRODUCT.

PRODUCT REGISTRATION

CyberPower requests that you complete and return the Warranty Registration Card enclosed with 
the Product or register the Product at its website (www.cyberpowersystems.com/registration) to 
establish that you are the Initial Customer of the Product, and therefore entitled coverage under the 
Limited Warranty (Registration is not required for coverage, but note: if you do not register your 
purchase, you will be required to provide proof of purchase.)

Содержание MBP63A2

Страница 1: ...respective owners I SMART APP ONLINE UPS SYSTEM MBP63A2 INSTALLATION AND OPERATION MANUAL 2020 Cyber Power Systems USA Inc All rights reserved K01 0000808 00 SAVE THESE INSTRUCTIONS Please read this m...

Страница 2: ...INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thorou...

Страница 3: ...uring the building installation RISK OF ELECTRIC SHOCK WARNING To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminant...

Страница 4: ...volving life support equipment and or patient care DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact wit...

Страница 5: ...NTRODUCTION 1 Maintenance Bypass PDU MBP 1 Whats In The Box 3 HARDWARE INSTALLATION 4 Front Panel Description 4 Brackets Installation 5 MBP Installation 6 ELECTRICAL INSTALLATION 7 Hardwiring The Inpu...

Страница 6: ...d personnel can use the bypass feature to disconnect the PDU from the UPS without disrupting power to connected equipment This feature allows connected equipment to operate seamlessly during maintenan...

Страница 7: ...Please contact CyberPower for assistance to upgrade the MCU version NOTE MCU version is the UPS Firmware version NOTE If the MBP Detection Cable is not used the Firmware is not required to be updated...

Страница 8: ...ackmount brackets 2 5 Flat head screws M4X6L 4 4 6 Pan head screws M5X8L 4 4 ITEM CONTENT QTY 7 Input output terminal block cover 2 8 Cage nut 4 9 MBP detection cable 3 3ft 1 10 L6 30P power cord 3 3f...

Страница 9: ...ocks connect to UPS 3 Bypass Red light LED indicator Bypass source ready 4 Normal Green light LED indicator UPS source ready OK to switch 5 MAINTENANCE BYPASS SWITCH 6 20A circuit breaker for L6 20 ou...

Страница 10: ...TION CONT The MBP can be mounted in a rackmount or vertical tower orientation Please follow the instructions below for the respective mounting methods 1 Brackets installation Attach the two brackets t...

Страница 11: ...ock only use the supplied hardware to attach the mounting brackets 2 MBP Installation Secure the MBP to rack CyberPower rack mounted UPS or a wall with the provided screws M5X8L 2pcs Caution Important...

Страница 12: ...cable through the appropriate cable gland and connect three wires L1 L2 and Ground to the OUTPUT MBP terminal block for connection to Load 3 Insert the input cable through the appropriate cable gland...

Страница 13: ...fix the terminal block bottom cover on the MBP 2 Insert the output cable through the conduits and connect three wires L1 L2 and Ground to the FROM UPS OUTPUT terminal block for connection to UPS outpu...

Страница 14: ...screws to separate the top and bottom covers 2 Put the L6 30P power cord and the L6 30R power cord into the bottom cover Screw the power cord cover with the bottom cover and fix the terminal block bo...

Страница 15: ...LATION CONT CONNECTING THE MAINTENANCE BYPASS PDU TO A UPS Connect the input output as shown in the following diagrams for different models OL5KRTHD OL6KRTHD TO NORMAL AC SOURCE Utility OUTPUT TO EQUI...

Страница 16: ...NSFORMER OL5KRTHD OL6KRTHD WITH A STEP DOWN TRANSFORMER TO NORMAL AC SOURCE Utility OUTPUT TO EQUIPMENT Load OUTPUT TO EQUIPMENT Load OL6KRT OL6KRTF WITH A STEP DOWN TRANSFORMER TO NORMAL AC SOURCE Ut...

Страница 17: ...ly transfer to bypass mode NOTE TO AVOID DAMAGE Follow the correct operation and start up procedures using either the MBP Detection Cable P12 or Retaining EPO ROO Function P18 OPERATIONS WITH MBP DETE...

Страница 18: ...se outlets can no longer be used loads can only be connected to the MBP outlets or the MBP Output terminal blocks 2 Verify that the MBP terminal blocks are connected to the Normal AC source Utility 3...

Страница 19: ...connecting the input output and MBP detection cable 11 Verify that the UPS is on Bypass mode by checking UPS display panel refer to the UPS user manual 12 Verify that the Normal green light of the MB...

Страница 20: ...f MBP switch and tighten 2 screws by screw driver 5 Press the UPS ON OFF power button for 3 seconds to turn off UPS and make sure UPS is turned in to standby mode and green light of the MBP goes Off 4...

Страница 21: ...ual Bypass for MBP detection refer to the UPS user manual as following UPS REPLACEMENT WITH MBP63A2 AND MBP DETECTION CABLE CONT 63A 250V UPS INPUT SWITCH 1 6 Set the UPS INPUT switch of the MBP to th...

Страница 22: ...ectly connected 7 Verify that the UPS is on Bypass mode by checking UPS display panel refer to the UPS user manual 8 Verify that the Normal green light of the MBP goes On indicating that the UPS outpu...

Страница 23: ...P Detection Cable P12 or Retaining EPO ROO Function P18 NOTE If the UPS is equipped with outlets those outlets can no longer be used loads can only be connected to the MBP outlets or the MBP Output te...

Страница 24: ...nput EPO or ROO Save Change 2 OL6KRT OL8KRT OL10KRT OL6KRTF OL8KRTF OL10KRTF models Configure Signal input EPO or ROO Save 9 Press the UPS ON OFF power button for 3 seconds to start the UPS UPS will b...

Страница 25: ...o the UPS user manual as following 1 OL5KRTHD OL6KRTHD models Controls Manual Bypass Disable Activate 2 OL6KRT OL8KRT OL10KRT OL6KRTF OL8KRTF OL10KRTF Configure Manual Bypass Disable Important After t...

Страница 26: ...refer to the UPS user manual Important before setting the UPS to bypass mode do not set the MBP manual Bypass switch to the Bypass position UPS will be damaged if this is not followed 3 Release two s...

Страница 27: ...PS INPUT SWITCH UPS OK FROM UPS OUTPUT 63A 250V TO UPS NORMAL AC SOURCE to switch Bypass Normal MAINTENANCE BYPASS SWITCH UPS INPUT SWITCH UPS OK RETURN TO NORMAL OPERATION 1 Check that the new UPS is...

Страница 28: ...ble on the MBP Important do not continue to next step if the Normal green light of the MBP is still Off the load will be lost 9 Release two screws by screw driver and open the Cover of MBP switch and...

Страница 29: ...l Block Wiring Information Use No 6 AWG minimum 90 C copper wire and 18 lb in Output Outlets 1 NEMA L6 20R 1 NEMA L6 30R 1 Terminal Block Physical Form Factor 2U Enclosure Construction Steel Dimension...

Страница 30: ...sferred to any third party and coverage ends if the Initial Customer sells or otherwise transfers the Product To be covered the Initial Customer must still be the owner of the Product at the time of t...

Страница 31: ...covers the Initial Customer that the Product will be free from original defects in material and workmanship for three years from the date of original purchase subject to the terms of this Warranty Who...

Страница 32: ...before bringing a claim for a breach of a warranty a claimant shall pursue a Warranty with CyberPower as set forth in this Warranty however to the extent the claimant s claim is not for a breach of w...

Страница 33: ...permitted by law this Warranty and the remedies set forth are your sole and exclusive remedy and are provided in lieu of all other warranties remedies and conditions whether oral written statutory ex...

Страница 34: ...perating conditions or in accordance with all labels or instructions What Other Limitations Apply The sole and exclusive remedies of the Initial Customer are those provided by this Warranty 1 This War...

Страница 35: ...ies CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums CyberPower does not authorize use of any Product in any High Risk Activities or...

Страница 36: ...yber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 877 297 6937 https www cyberpowersystems com support support request start Need Additional Help See Operation and Installation Manu...

Страница 37: ...espective owners 32 Cyber Power Systems USA Inc www CyberPowerSystems com For USA and Canada 4241 12th Ave East Suite 400 Shakopee MN 55379 Toll free 877 297 6937 For all other regions Please visit ou...

Отзывы: