TECHNICAL SPECIFICATIONS

DEFINITIONS FOR ILLUMINATED LED INDICATORS

LED

Alarm

Condition

On

Off

Normal

Flash

Beep Twice

Utility Failure - The UPS is providing battery power to outlets.

Flash

Rapid

Beeping

Utility Failure - The UPS is providing battery power. The rapid beeps indicate

the battery will run out of power shortly.

On/Flash

Constant

Tone

Overload - Occurs when connected equipment exceeds the rating of the unit.

Turn the UPS off and unplug at least one piece of equipment from the UPS.

TROUBLESHOOTING

Problem

Possible Cause

Solution

The UPS does not perform

expected runtime.

Batteries are not fully charged.

Recharge the battery by leaving the

UPS plugged in.

Battery is slightly worn out.

Contact CyberPower Systems

Technical Support.

The UPS will not turn on.

The unit is not connected to an AC

outlet.

The unit must be connected to a

220-240V outlet.

The battery is worn out.

Contact CyberPower Systems

Technical Support.

Mechanical problem.

Contact CyberPower Systems

Technical Support.

Outlets do not provide power to

equipment

Fuse is blown or breaker is tripped

due to overload.

Turn the UPS off and unplug at least

one piece connected equipment.

Unplug the power cord of the UPS then

replace the blown fuse with a spare

one or press the circuit breaker knob.

Connect power cord then turn the UPS

on. Make sure that your spare fuse

meets the specification.

Batteries are discharged

Allow the unit to recharge for at least 4

hours.

Unit has been damaged by a surge or

spike.

Contact CyberPower Systems

Technical Support.

For more information, visit

www.cyberpower.com

All rights reserved. Reproduction without permission is prohibited.

6F, No. 32, Sec. 1, Chenggong Rd., Nangang District, Taipei 115, Taiwan

Model

BU650E

BU1000E

Capacity (VA)

650

1000

Watt (W)

360

600

Input
Voltage Range

165~280Vac

Nominal Frequency

50 Hz

Output
On Battery Output Voltage

Simulated Sine Wave at /-5%

On Battery Output Frequency

50 Hz +/-1%

Overload Protection

Breaker / Fuse

Physical

Total UPS Receptacles

3

4

Dimensions (H x W x D)(mm)

91.5 x 158 x 240

110.5 x 190 x 290

Weight

3.8 kg

6.9 kg

Battery

Sealed Maintenance Free Lead Acid
Battery

RBP0019 x1

RBP0119 x2

Typical Recharge Time

8 Hours

Warning Diagnostics

Indicators

Power On / Using Battery

Audible Alarms

On Battery, Low Battery, Overload, Fault

Environmental

Operating Temperature

0

C to 40

C

Operating Relative Humidity

0 to 90%

Management

Auto-Charger

Yes

Auto-Restart

Yes