CyberPower BPE48V75ART2U Скачать руководство пользователя страница 6

 

Copyright © 2009 CyberPower Systems, Inc.

 

Hardware Installation Guide 

Safety Precautions

 

 

CAUTION! Before connecting the Battery Pack(s) to the UPS, completely turn off and 

unplug the main UPS from the wall receptacle. 

 

CAUTION! Do not disconnect the any Battery Packs when the UPS is turned on or 

plugged into a wall receptacle. 

 

CAUTION! Do not connect the battery pack into itself. 

 

CAUTION! Do not add more Battery Packs to the UPS than is specified in the 

Technical Specifications section of the User’s Manual.    This will damage the unit 

and void the warranty.

 

Rackmount Installation

 

Step 1: Rackmount ear and handle installation 

 

 

 

 

 

 

 

 

 

Step 2: Rackmount Rail Installation 

Each  Rackmount  Rail  (Left  and  Right)  consists  of  two  pieces  that  must  be  assembled 

together before installing into the rack.

 

 

 

 

 

 

 

 

Attach the two Rackmount Ears to 

Battery  Pack  using  the  provided 

screws. 

Attach  the  Rackmount  Handles 

to  the  Rackmount  Ears  using 

the provided screws. 

Содержание BPE48V75ART2U

Страница 1: ...User s Manual BPE48V75ART2U Battery Pack K01 0000127 01...

Страница 2: ...TECHNICAL SPECIFICATIONS 3 INSTALLATION INSTRUCTIONS 4 Package Contents 4 HARDWARE INSTALLATION GUIDE 5 Safety Precautions 5 Rackmount Installation 5 Vertical Standing Installation 7 ELECTRICAL INSTAL...

Страница 3: ...and tower mounting Scalable Up to four battery packs can be daisy chained together for increased runtimes Metal Housing Rigid metal construction provides greater durability and safety Power On Off Swi...

Страница 4: ...Maintenance Free Yes User Replaceable Yes Battery Life 3 5 Years Compatibility UPS Compatibility PR1000 1500 2200ELCDRTXL2U PR3000ELCDRT2U Scalability Battery Packs Unlimited Up to 5 for PR3000ELCDRT...

Страница 5: ...iary AC Power Cord Rack mount Ears 2 Rack mount Ear Screws 14 Battery Pack Unit Rack mount Handles 2 Rack mount Handle Screws 5 Screw Hole Dust Covers 5 Screw Hole Dust Cover Screws 5 Rackmount Rails...

Страница 6: ...nto itself CAUTION Do not add more Battery Packs to the UPS than is specified in the Technical Specifications section of the User s Manual This will damage the unit and void the warranty Rackmount Ins...

Страница 7: ...r rack Once complete perform the same steps for assembling the Rackmount Rail inscribed with an R Right Attach the Rackmount Rails to your rack using fasteners that are designed for your rack system C...

Страница 8: ...ands to make room for the Base Stand Expanders Take the Base Stand Expanders and insert them in between the separated Base Stands Be sure the pieces firmly snap together Step 2 Install Battery Pack Th...

Страница 9: ...ION Do not disconnect the any Battery Packs when the UPS is turned on or plugged into a wall receptacle CAUTION Do not connect the battery pack into itself CAUTION Do not add more Battery Packs to the...

Страница 10: ...Battery Pack power switch ON Step 5 Turn on your UPS system Plug your UPS system into the wall receptacle and safely power up your UPS system and connected equipment Battery Pack Configuration In ord...

Страница 11: ...ny battery packs are attached The default is zero To change this number press and hold the Select button for four seconds Now simply press the Select button and change the number to match how many Bat...

Страница 12: ...n in whole or in part without permission is prohibited Problem Possible Cause Solution The UPS LCD does not perform expected runtime Do not set the UPS to recognize the battery pack s By pressing the...

Отзывы: