Technical Specifications 

 

General 

  Model     

 

                              BPE48V75ART2U 

Input 

 

Nominal Input Voltage                       48 VDC, 230VAC 

 

Overload Protection                          AC, DC circuit protection 

Batteries 

 

Specifications 

 

                      (8 of batteries) 12V/ 9.0AH 

 

Sealed Maintenance Free   

      Yes 

 

User Replaceable  

 

              Yes 

 

Battery Life   

 

 

              3-5 Years 

Compatibility 

 

UPS Compatibility 

                      PR1000/1500/2200ELCDRTXL2U,   

PR3000ELCDRT2U 

Scalability 

 

Battery Packs 

 

 

              Unlimited (Up to 5 for PR3000ELCDRT2U) 

Charging 

 

Built-in Charger   

 

              Yes 

Physical

 

 

Dimensions (cm)   

                      2U Rack, 43.3 x 8.8 x 48 

 

Weight (kg)   

 

 

              35 

Environmental 

 

Temperature – Operating   

      32°F – 104°F 

 

Humidity – Operating   

 

      0% to 95% Non-condensing 

Safety Approvals

 

 

Certifications  

 

 

              CE 

 

RoHS 

 

 

 

 

              RoHS Compliant 

 

 

 

Содержание BPE48V75ART2U

Страница 1: ...User s Manual BPE48V75ART2U Battery Pack K01 0000127 01...

Страница 2: ...TECHNICAL SPECIFICATIONS 3 INSTALLATION INSTRUCTIONS 4 Package Contents 4 HARDWARE INSTALLATION GUIDE 5 Safety Precautions 5 Rackmount Installation 5 Vertical Standing Installation 7 ELECTRICAL INSTAL...

Страница 3: ...and tower mounting Scalable Up to four battery packs can be daisy chained together for increased runtimes Metal Housing Rigid metal construction provides greater durability and safety Power On Off Swi...

Страница 4: ...Maintenance Free Yes User Replaceable Yes Battery Life 3 5 Years Compatibility UPS Compatibility PR1000 1500 2200ELCDRTXL2U PR3000ELCDRT2U Scalability Battery Packs Unlimited Up to 5 for PR3000ELCDRT...

Страница 5: ...iary AC Power Cord Rack mount Ears 2 Rack mount Ear Screws 14 Battery Pack Unit Rack mount Handles 2 Rack mount Handle Screws 5 Screw Hole Dust Covers 5 Screw Hole Dust Cover Screws 5 Rackmount Rails...

Страница 6: ...nto itself CAUTION Do not add more Battery Packs to the UPS than is specified in the Technical Specifications section of the User s Manual This will damage the unit and void the warranty Rackmount Ins...

Страница 7: ...r rack Once complete perform the same steps for assembling the Rackmount Rail inscribed with an R Right Attach the Rackmount Rails to your rack using fasteners that are designed for your rack system C...

Страница 8: ...ands to make room for the Base Stand Expanders Take the Base Stand Expanders and insert them in between the separated Base Stands Be sure the pieces firmly snap together Step 2 Install Battery Pack Th...

Страница 9: ...ION Do not disconnect the any Battery Packs when the UPS is turned on or plugged into a wall receptacle CAUTION Do not connect the battery pack into itself CAUTION Do not add more Battery Packs to the...

Страница 10: ...Battery Pack power switch ON Step 5 Turn on your UPS system Plug your UPS system into the wall receptacle and safely power up your UPS system and connected equipment Battery Pack Configuration In ord...

Страница 11: ...ny battery packs are attached The default is zero To change this number press and hold the Select button for four seconds Now simply press the Select button and change the number to match how many Bat...

Страница 12: ...n in whole or in part without permission is prohibited Problem Possible Cause Solution The UPS LCD does not perform expected runtime Do not set the UPS to recognize the battery pack s By pressing the...

Отзывы: