Advanced Energy-Saving Patented Bypass Technology

CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy 

costs by up to 75% compared to conventional UPS models. Even when utility power 

is normal, conventional UPS models constantly pass power through a transformer. 

By contrast, under normal conditions the advanced circuitry of a GreenPower UPS™ 

bypasses the transformer. As a result, the power efficiency is significantly increased 

while decreasing waste heat, using less energy, and reducing energy costs. When an 

abnormal power condition occurs, the GreenPower UPS™ automatically runs power 

through its transformer to regulate voltage and provide “safe” power. Since utility power is normal over 88% of 

the time, the GreenPower UPS™ operates primarily in its efficient bypass mode. The GreenPower UPS™ is also 

manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one  

of the most environmentally-friendly on the market today.

CYBERPOWER GREENPOWER UPS™ TECHNOLOGY

G

REEN

P

OWER 

UPS

Energy-Saving Technology

Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected 

Equipment Guarantee. 

Where Can I Get More Information?  

     

The application of the United Nations Convention of Contracts for the International Sale of  

Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.  

For further information please feel free to contact CyberPower at: 

Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379;  

call us at 

(877) 297-6937

; or submit a web ticket online at 

cyberpowersystems.com/support

.

Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal  

and recycling of its UPS products. Please dispose and/or recycle your UPS and batteries in  

accordance to the local regulations of your state.

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation.  

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses, and can 

radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference will not occur in a particular  

installation. If this equipment does cause harmful interference to radio or television reception, which can be determined 

by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 

following measures:  

- Reorient or relocate the receiving antenna.  

- Increase the separation between the equipment and receiver.  

- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.  

- Consult the dealer or an experienced radio/TV technician for help.  

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the 

user’s authority to operate the equipment.
 

Canadian Compliance Statement  

CAN ICES-3 (B)/NMB-3(B)

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE

FCC COMPLIANCE STATEMENT

© 2022 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc.

All rights reserved. All other trademarks are the property of their respective owners.

WARNING:

 This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the  

State of California to cause reproductive harm and cancer.  For more information, go to www.P65Warnings.ca.gov.

Содержание OR500LCDRM1U

Страница 1: ...379 CyberPowerSystems com FEATURES 1 LCD Module Display 2 Power On Indicator 3 Power Switch 4 LCD Function Selected Switch 5 Battery and Surge Protected Outlets 6 Full Time Surge Protection Outlets 7 SNMP HTTP Network Slot 8 Communication Protection Ports RJ45 9 USB Port to PC 10 Dry Contact 11 Circuit Breaker 12 AC Input 13 Electrical Wiring Fault Indicator Red ...

Страница 2: ...lling a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 CAUTION Do not dispose of batterie...

Страница 3: ...or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your electronic equipment will require For optimal system performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to ensure the battery s maximum charge capacity it is recommended t...

Страница 4: ...re DO NOT plug a laser printer paper shredder copier space heater vacuum cleaner sump pump or other large electrical devices into the Battery and Surge Protected Outlets The power demands of these devices may overload and damage the unit 6 Full Time Surge Protection Outlets The unit has two surge suppression outlets 7 SNMP HTTP Network Slot Remove the cover panel to install an optional RMCARD prov...

Страница 5: ... 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock ...

Страница 6: ...V 3rd V X X X V V 4th V X X V X V 5th Return V X X V X V Overload V X V Select SW Press UPS Status Display Capacity Display Digital Value Display Load Cap Battery Cap Input Voltage Output Voltage of Load of Batt Run Time Initial X V X X V V 1st X V X X V V 2nd X V X V X V 3rd X V X X V V 4th X V X X V V 5th Return X V X X V V Overload X V V Line Mode Battery Mode V Illuminated X Not Illuminated Ei...

Страница 7: ...t CyberPower Systems about replacement batteries at cyberpowersystems com support The UPS will not turn on The on off switch is designed to prevent damage from rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The battery is worn out Contact CyberPower Systems about replacement batteries at cyberpowersystems com support Mechanical problem Contact CyberPower Sy...

Страница 8: ...NON CONDENSING Size W x H x D 433 x 235 x 44 mm 1U Rack 17 05 x 9 25 x 1 75 in Net Weight 16 5 lbs 7 47 kg 17 3 lbs 7 83 kg Battery Type CyberPower RB0670X2 CyberPower RB0690X2 Typical Battery Recharge Time 8 hours Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Safety Approvals UL1778 4th cUL CSA C22 ...

Страница 9: ...ur state This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of ...

Отзывы: