Instruction manual
FO SERIAL
Page 21
10.2. Appendix B - Jumpers configuration
For user security reasons, any intervention on the equipment and more particularly opening the box must only be done by competent
staff and the equipment must be imperatively disconnected from the power supply.
10.2.1. DIP SWITCH for FO SERIAL
By default, the FO SERIAL is configured in production in FOSE11, FOSE35, FOSE28 mode depending of the client order. But a technician can
change the product by moving the jumpers. See configuration jumpers.
Jumper J15 connect ground and shield together.
Jumper J16 is unused.
INTERFACE
JUMPER V28: FO SE28
X21-V11: FO SE11
V35 : FO SE35
J1
Position 1-2
Position 2-3
Position 2-3
J2
Position 1-2
Position 2-3
Position 1-2
J3
Position 1-2
Position 2-3
Position 1-2
J4
Position 1-2
Position 2-3
Position 1-2
J5
Position 1-2
Position 2-3
Position 1-2
J6
Position 1-2
Position 2-3
Position 2-3
J7
Position 1-2
Position 2-3
Position 1-2
J8
Position 1-2
Position 2-3
Position 2-3
J9
Position 1-2
Position 2-3
Position 2-3
J10
Position 1-2
Position 2-3
Position 2-3
J11
Position 1-2
Position 2-3
Position 1-2
J12
Position 1-2
Position 2-3
Position 2-3
J13
Position 1-2
Position 2-3
Position 1-2
J14
Position 1-2
Position 2-3
Position 2-3
J18
Close
Close
Close
J19
Close
Close
Close
J20
Close
Close
Open
J21
Close
Open
Close