background image

C.A.R.E 2000

Technical Specification Summary

AIR PURIFICATION SYSTEM

DIMENSIONS

HEIGHT - 28 INCHES   

 

WIDTH - 15 INCHES 

 

DEPTH - 14 INCHES

FILTER MATERIAL

80 SQ.FT. OF TrueHEPA MEDIA RATED AT 99.97% AT 0.3 MICRONS; NON
OUT-GASSING, 10" HIGH  X 13.5" DIAMETER
15 LBS. ACTIVATED CARBON MEDIA WITH A COMBINED 422 MILLION SQ.
INCHES OF TOTAL ABSORPTIVE SURFACE AREA FOR GAS AND CHEMI-
CAL REDUCTION.

PRE-FILTERS

REMOVABLE INERT CARBON IMPREGNATED SPUN POLYESTER PRE-
FILTER CAN BE WASHED OR VACUUMED TO EXTEND LIFE.
90% REDUCTION OF LARGE PARTICLES >10 MICRON TO PROTECT THE
HEPA.  48" LENGTH X 10" HEIGHT SURROUNDS HEPA CARBON FILTER.

POST FILTER

CARBON IMPREGNATED POLYESTER PAD FOR ADDITIONAL ABSORP-
TION. "SAFE FLOW" INDICATOR LIGHT SIGNALS YOU TO CLEAN OR
REPLACE FILTERS.
SEALING GASKETS AROUND EDGES ASSURE AIR FLOW THROUGH THE
FILTER.

ELECTRICAL

WATTAGE - 130 WATTS   

   

HERTZ - 60 CYCLE     

 

AMP - 1 AMP

FAN/MOTOR ASSEMBLY

350 CFM, 2500 RPM CENTRIFUGAL BACKWARD INCLINED FAN OF REIN-
FORCED POLYAMIDE IS STRONGER THAN STEEL; WITH MINIMAL VIBRA-
TION CREATING HIGH AIR FLOW WITH LOWER ELECTRICAL USAGE.
MOTOR IS A HIGH EFFICIENCY SPLIT CAPACITOR FOR CONTINOUS LONG
LIFE DUTY.
ADJUSTABLE SPEEDS TO GIVE FINELY-TUNED AIR CHANGE.
LOW NOISE AND VIBRATION DURING OPERATON.
UNIT IS CSA/NRTL CERTIFIED, A WORLD-WIDE TRADEMARK.
OVER 21,000 CUBIC FEET OF AIR CLEANED EVERY HOUR.

ULTRAVIOLET LAMPS

TWO 9 WATT LAMPS PRODUCT GERMICIDAL DOSAGE TO KILL BACTERIA,
VIRUSES AND YEAST.
LOCATED IN AN INTERNAL CHAMBER OF POLISHED STEEL.
9,000 HOUR OPERATION CAPABILITY.
REPLACEABLE BULBS.

HOUSING CONSTRUCTION

22 GAUGE GALVANIZED STEEL WITH A POWDER PAINT COATING TO
ALLOW FOR EASY CLEANING AND DURABILITY.
UNIT OUT FLOW VIA TOP LOUVERS TO PROVIDED MAXIMUM ROOM AIR
CHANGES.
FILTER ACCESS FROM REAR DOOR OPENS WITH A SIMPLE TWIST OF 2
SCREWS.
UNIT WEIGHT: 48 POUNDS

 

SHIPPING WEIGHT: 53 POUNDS

7

Содержание C.A.R.E. 2000

Страница 1: ...n the market Cleans up to 1 500 sq ft area CSA Approved Certi fied for North America Europe Patented Top Flow Design air discharge 5 stages of filtration Operations Manual C A R E Instructions Now I can breathe the air of the new millennium the air my body needs and deserves Thank you T E Grissom Solana Beach CA ...

Страница 2: ...eria yeasts and mold are trapped in the HEPA filter and tend to grow Continuous running of the filter is necessary to dry out these organisms and keep growth to a minimum The Ultraviolet system will also keep any microbiologically contaminated air from passing through but the lamps must be replaced once a year to keep the germicidal level effective If for any reason the C A R E 2000 is not run for...

Страница 3: ...ts The following chart will help you determine how many air changes your unit will provide in a given space AIR FLOW PATTERN The C A R E 2000 has an adjustable speed setting We recommend that the unit re mains in the low to medium setting speed For maximum number of air changes ACH set the unit to high e z i s m o o R e g a r e v A x h t d i W x h t g n e L t h g i e H t e e F c i b u C r i A f o ...

Страница 4: ...ewoneachsideandonthe back of the unit 3 screws total FIG 2 The back screw on top of rear access panel is a shipping screw and does not need to be replaced 2 Gently rest unit label face down DO NOT REST ON WHEELS Remove the 2 shipping screws on the bottom of the unit These screws are for shipping and do not need to be replaced FIG 3 3 Remove 2 screws on the bottom of the rear access panel FIG 4 Pul...

Страница 5: ...r changes may be shorter IF THE RED INDICATOR LIGHT REMAINS ON If cleaning or changing the pre filter does not shut off the red indicator light this signal means that the inner HEPA filter needs to be changed Call your distributor and order a HEPA replacement filter HOW TO CHANGE THE HEPA CARBON FILTER 1 UNPLUGTHEUNITBEFORE SERVICING 2 Follow steps 1 to 4 in the HOW TO CLEAN YOUR PRE FILTER sectio...

Страница 6: ... shipping tie fromaround the base of each Ultraviolet lamp BE CAREFUL NOT TO CUT THE WHITE LAMP WIRE FIG 9 While holding the lamp socket with one hand gently pull the lamp straight out from its socket 4 Discard the old lamps place them in a trash bag and throw them away 5 DO NOT TOUCH the glass of the New Ultraviolet lamps with your hands as the oil on your skin may alter the performance of the la...

Страница 7: ... ELECTRICAL WATTAGE 130 WATTS HERTZ 60 CYCLE AMP 1 AMP FAN MOTOR ASSEMBLY 350 CFM 2500 RPM CENTRIFUGAL BACKWARD INCLINED FAN OF REIN FORCED POLYAMIDE IS STRONGER THAN STEEL WITH MINIMAL VIBRA TION CREATING HIGH AIR FLOW WITH LOWER ELECTRICAL USAGE MOTOR IS A HIGH EFFICIENCY SPLIT CAPACITOR FOR CONTINOUS LONG LIFE DUTY ADJUSTABLE SPEEDS TO GIVE FINELY TUNED AIR CHANGE LOW NOISE AND VIBRATION DURING...

Страница 8: ...OR LIABILITIES EXPRESSED OR IMPLIED THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTSAND YOU MAYALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE PLEASEFAXTHISWARRANTYORMAILTHEENCLOSEDWARRANTYCARD OR REGISTER ONLINE www cwrenviro com warranty htm CWR ENVIRONMENTAL PRODUCTS 100 CARNEY STREET GLEN COVE NY 11542 TELEPHONE 516 674 2441 FAX 516 674 3788 8 S T R A P Y T N A R R A W R E D N U S L E E...

Страница 9: ..._____ _____ Cardholders Name ________________________________________ Signature __________________________________________________ Please allow 2 3 weeks for delivery QTY ITEM PRICE TOTAL CARE 2000 PRE FILTER POST FILTER SET A Check Enclosed Money Order Enclosed Mastercard Visa Discover AmEx CARBON HEPA DRUM COMPLETE REPLACEMENT PK A B C ULTRAVIOLET LAMPS B 2 PK Subtotal Shp Hdl NYS Residents 8 5 ...