P.O. Box 749 Peekskill, NY 10566 Tel: (845) 737-7009 Fax: (845) 737-0426 Web: www.compuvideosystems.com
MULTI-SWITCHER SETUP:
A CS-1600 can be used as a master switcher to be fed by the DA-3212 slave switchers,
or a DA-3212 can be set up as a master if desired. To connect multiple units together to
enlarge the number of inputs you must set the slave units up for the proper addresses.
A) Determine which unit will be the master. All units are preset as masters from the
factory. Put it aside.
B) On each of the slave units:
Disconnect the power to the unit.
Remove the switcher card
Using the master slave diagram Fig. 13, locate:
The Master/slave suitcase jumper
The 8 pos Dip switch
C)
Determine the ID number to be used for each slave unit
,
(i.e. unit 16, or 15 or 14....). Mark the unit as to the ID number it is set for. Written in
pencil on the bottom will do the trick!
D) Set the suitcase jumper to the Slave position as shown in the master slave jumper
setup diagram.
E) Set dip switch #5 to the off position.
There is an eight position dip switch located on the control board. It is factory set for
machine #1 and the suitcase jumper is set for a master unit. To add addition units you will
start at the highest number and count down as shown in the system diagram. The master
will always be machine 1 unless there are 16 slave units. The slaves will start at 16 and go
down to 1 as they are added.
SWITCH CODE
SWITCH
MACHINE NUMBER
4
3
2
1
0000
ON
ON
ON
ON
1
0001
ON
ON
ON
OFF
2
0010
ON
ON
OFF
ON
3
0011
ON
ON
OFF
OFF
4
0100
ON
OFF
ON
ON
5
0101
ON
OFF
ON
OFF
6
0110
ON
OFF
OFF
ON
7
0111
ON
OFF
OFF
OFF
8
1000
OFF
ON
ON
ON
9
1001
OFF
ON
ON
OFF
10
1010
OFF
ON
OFF
ON
11
1011
OFF
ON
OFF
OFF
12
1100
OFF
OFF
ON
ON
13
1101
OFF
OFF
ON
OFF
14
1110
OFF
OFF
OFF
ON
15
1111
OFF
OFF
OFF
OFF