CustomControls ValveSentry Скачать руководство пользователя страница 4

CustomControls, LLC 

 

BASIC SAFETY INFORMATION 

IMPORTANT! 

•   “

DANGER

,” “

WARNING

,” and “

CAUTION

” alert you to important operating instructions or to potentially hazardous situations. Pay special 

attention to these items. 

 

DANGER

: The ValveSentry™ device is powerful.

  It has considerable torque allowing it to open and shut your valve.  THEREFORE ALWAYS KEEP 

YOUR HANDS AND FINGERS AWAY FROM THE DEVICE while it is powered.  If your hand or finger gets caught on a valve or is between the valve 
and a pipe, wall or other object while a valve is opening or closing, it could cause injury.  That is why you should always unplug and remove 
the batteries from the unit prior to installing, adjusting or touching it.  Remember that you can always immediately shut down the unit by 
pressing the “stop” button on the controller.

 

 

 

WARNING:

 Before you turn off a water source

.  Be aware of any consequences that can result from your valve being turned off by the 

ValveSentry™ device before installing it.  For example, some heating systems can be damaged if water is cut off for any length of time.  
CustomControls LLC is not responsible for such damage.    Therefore, please deploy the ValveSentry™ device in a thoughtful manner

 

 

CAUTION: 

The ValveSentry™ device has limitations.  

This

 

ValveSentry™ device is not foolproof and is not warranted to protect lives and 

property from water damage and associated hazards such as electric shock.  The ValveSentry™ device is not a substitute for insurance.  
Homeowners and renters should insure their lives and property.  In addition, it is possible, although unlikely, for the ValveSentry™ device to 
fail at any time.  

For this reason you must test the ValveSentry™ device monthly, assure it has fresh batteries and is working properly.  It is 

recommended that you replace it with a new ValveSentry™ device

 

every 5 years. 

 

 

CAUTION: 

The ValveSentry™ device is NOT a solution for a “stuck” or frozen valve.  The valve that is being protected must be in good 

working order for the ValveSentry™ device to be effective.  If you cannot turn off your valve using normal hand strength, the ValveSentry™ 
device cannot turn off your valve.  

 

BATTERIES: 

THE VALVESENTRY BATTERY HOLDER INCLUDES EITHER A SHORT BAR OR A DUMMY BATTERY. 

DO NOT REPLACE THIS WITH A REGULAR BATTERY. DOING SO WILL DESTROY THE VALVESENTRY. THE 
VALVESENTRY ONLY REQUIRES 7 AAA BATTERIES. TEST THE VALVE SENTRY TO MAKE SURE THAT IT WORKS ON 
BATTERY POWER EVERY THREE MONTHS. 

Содержание ValveSentry

Страница 1: ...6 IMPORTANT PLEASE READ CAREFULLY AND SAVE This user s manual contains important information about your ValveSentry device s operation If you are installing this ValveSentry device for use by others y...

Страница 2: ...on 4 What s in the Box 5 Installation Instructions 6 Installation on a Gate Valve 7 Installation on a Ball Valve 10 Water Sensor Placement 11 Connecting the Controller 12 Battery Installation IMPORTAN...

Страница 3: ...This device has a one year limited warranty see below for details Please take a few minutes to thoroughly read this user s guide and save for future reference The more familiar you are with the infor...

Страница 4: ...such damage Therefore please deploy the ValveSentry device in a thoughtful manner CAUTION The ValveSentry device has limitations This ValveSentry device is not foolproof and is not warranted to protec...

Страница 5: ...aded Rod Motor Motor Bracket Gate Valve handle mount top and bottom discs and 3 screws 2 shown What s in the Box Water Sensor Ball Valve handle mount and screws comes pre assembled See page 10 U Clamp...

Страница 6: ...TION INSTRUCTIONS The following installation instructions should allow you to install the ValveSentrytm device in a short period of time You will need a Phillips head screw driver and a wrench to tigh...

Страница 7: ...e Step 1 Place bottom disc under gate valve handle Step 2 Place top disc on top of Gate valve handle centering the shaft over the center of the handle and lining up at least two slots to slip 4 screws...

Страница 8: ...unt bracket contains a number of holes and is shaped so that it can be mounted to the right side left side front or the back of the motor Mounting on the top surface if possible is desirable for most...

Страница 9: ...and motor mount bracket in desired positions so that the threaded rod will pass through plastic bushing hole in pipe mount bracket Step 9 Install proper size U bolts around pipe and through the slots...

Страница 10: ...racket Figure B What handle bracket should look like when properly installed Step 1 Install the top disc on top center of Ball Valve Handle Mount Step 2 Slide the assembly as shown below over the valv...

Страница 11: ...11 CustomControls LLC Place Water Sensor in location to be monitored Multiple water sensors can be used Route wires to Controller being careful not to short or break them...

Страница 12: ...in the Power Supply to a 120 Volt properly grounded power outlet Step 3 Connect wires from water sensor to water sensor terminals on Controller The polarity or wires is not important Multiple sensors...

Страница 13: ...f your hand or finger gets caught on a valve or is between the valve and a pipe wall or other object while a valve is opening or closing it could cause injury That is why you should always unplug and...

Страница 14: ...normal force A rusted or jammed valve cannot be operated by the ValveSentry device 3 If the Valve functions properly perform step 1 of the test procedure above The ValveSentry should close and open th...

Страница 15: ...but that same battery will fail when it needs to provide high current to power the motor Test the valve the ValveSentry device is attached to making certain it can be opened and closed completely If t...

Страница 16: ...ervice center Further the warranty does not cover acts of God such as fire flood hurricanes and tornadoes or any batteries that are included with this unit EXCEPT AS SET FORTH IN WRITING IN THIS USER...

Страница 17: ...implied written or oral including that of merchantability or fitness for any particular purpose with respect to battery For your records please record Date Purchased _______________Where Purchased __...

Отзывы: