Custom Design & Fabrication Monkey PWH-100/3 Скачать руководство пользователя страница 33

 

33 

1040 

1/4 INCH BARB x 1/4 INCH MALE NPT BRASS 

1041 

1/2 INCH BARB x 3/8 INCH MALE NPT BRASS 

1042 

1/2 INCH CLOSE NIPPLE BRASS 

1043 

1/4 INCH 90 DEGREE STREET ELBOW BRASS 

1044 

1 1/4 INCH x 3/4 INCH BUSHING BRASS 

1045 

1/2 INCH FULL FEMALE T BRASS 

1046 

3/4 INCH  GH x 1/2 INCH NPT BRASS 

1046B(1146

1/2 INCH IPS BALL VALVE BRASS 

1047 

1/2 INCH x 3 1/2 INCH LONG NIPPLE BRASS 

1050 

1/2 INCH x 1/4 INCH BUSHING BRASS 

1051 

3/8 INCH NPT x 1/4 INCH HOSE BARB BRASS 

1052 

1/2 INCH FULL FEMALE 90 DEGREE ELBOW  BRASS 

1053 

1/2 INCH x 2 INCH LONG NIPPLE 

1054 

1/2 INCH x 11 INCH LONG NIPPLE BRASS 

1055 

3/16 INCH FLARE NUT BRASS 

1056 

FLARE BY MALE ELBOW BRASS 

1057 

FLARE BY MALE STRAIGHT CONNECTOR BRASS 

1058 

1/4 INCH x 3/16 INCH BUSHING BRASS 

1059 

1/4 INCH HOSE  BARB x 1/2 INCH FEMALE NPT BRASS 

1060 

1/4 INCH HOSE  BARB x 1/4 INCH FEMALE NPT BRASS 

1062 

PRIMARY SENSOR WET WELL 

1063 

ELECTRICAL CONDUIT 1/2 INCH NON METALIC PER FOOT 

1064 

ELECTRICAL CONDUIT 1/2 INCH NON METALIC PER FOOT 

1065 

ELECTRICAL CONDUIT 1/2 INCH NON METALIC PER FOOT 

1066 

ELECTRICAL CONDUIT 1/2 INCH NON METALIC PER FOOT 

1067 

120 VOLT RECEPTICE 15 AMP 

1068 

FUEL REGULATOR ASSEMBLY 

1068B(1168

0-200 FUEL GAUGE 

1069 

MANAFOLD FEED HOSE 

1072 

PUMP UMBILICAL 

1073 

CHASSIS 

1074 

FUEL LINE FEED 1/4 INCH PER FOOT 

1075 

FUEL PUMP FEED PER FOOT 

1076 

FUEL BYPASS LINE PER FOOT 

1077 

FUEL REGULATOR INLET 

1078 

FUEL REGULATOR DISCHARGE 

1079 

FUEL BURNER FEED 

1080 

FUEL TANK CAP 

1081 

BYPASS CONNECT HOSE PER FOOT 

1082 

PUMP CARRY CASE 

1083 

JUNCTION BOW ASSEMBLY 

1084 

UNIT ELECTRICAL FEED 

1085 

BURNER TRANSFORMER 

1086 

BURNER MOTOR 

Содержание Monkey PWH-100/3

Страница 1: ...1 Operations Manual Monkey Hot Water Heater Model PWH 100 3 120VAC 60HZ 20AMP Manufactured By Custom Design Fabrication Do Not Remove This Page...

Страница 2: ...ny Part of the System Does Not Function Properly Manufacturer and Distributors are not Responsible for Misuse of this Equipment Monkey Heater Specifications The Monkey Hot Water Heater System is a com...

Страница 3: ...salt water is excess of 135 degrees F for it may crystallize inside the coils Fuel consumption is dependent on the size of the fuel nozzle in use For example a 0 75 size nozzle will use approximately...

Страница 4: ...ID hose the minimum recommended flow rate is 4 g p m b Heat Loss from hot water hose NOTE The heat loss is dependent on ID and OD of hose length of hose ambient air and water and length of hose in the...

Страница 5: ...should be set at add the recommended suit injection temperature and the hot water heat loss These figures are based on extreme ambient weather conditions If the ambient air is warm then heat loss will...

Страница 6: ...PUMPING CONCRETE OR OTHER HAZARDOUS MATERIALS ARE PRESENT IN THE WATER SUCH MATERIALS CAN DAMAGE THE PUMP AND HEATER SYSTEM AND CAUSE SEVERE BURNS AND SKIN IRRITATIONS TO THE DIVER WARNING ALWAYS DIS...

Страница 7: ...h either 1 or 2 diesel oil 5 Make sure a flow of water is present through the system WARNING NEVER OPERATE THE FUEL PRESSURE AT THE REGULATOR LESS THAN 100 PSI FAILURE TO OBSERVE THIS WARNING WILL RES...

Страница 8: ...OPERATED BY THE DIVER TO ELIMINATE WATER FLOW IF NECESSARY IN THE EVENT OF A UNIT MALFUNCTION SEVERE BURNS MAY OCCUR 10 Once a comfortable working temperature has been achieved fine adjustments can b...

Страница 9: ...nit the pump receptacle and stop water flow through the unit in the event of a secondary high limit trip NOTE IF THE SECONDARY HIGH LIMIT CIRCUIT TRIPS THE WATER TEMPERATURE IN THE SYSTEM MUST DROP 15...

Страница 10: ...R WARNING ALWAYS KEEP CONTROL PANEL COVER CLOSED DURING INCLEMENT WEATHER TO PREVENT DAMAGE TO ELECTRICAL COMPONENTS IN THE SYSTEM WARNING SHOCK HAZARD DO NOT TOUCH ANY ELECTRICAL COMPONENTS IN THIS S...

Страница 11: ...ct all pump fittings Invert the pump to remove all water 5 Submerge the pump in a BIO safe solution of anti freeze 6 Reconnect the pump to the power supply to flood the system with anti freeze Pump um...

Страница 12: ...correctly WARNING DO NOT OPERATE UNIT IF ANY COMPONENT IN THE SYSTEM IS NOT FUNCTIONING CORRECTLY TO DO SO COULD CAUSE SEVERE BURNS TO THE DIVER OR CAUSE DAMAGE TO THE SYSTEM WEEKLY MAINTENANCE 1 Dis...

Страница 13: ...for unit function 4 Change fuel filter 5 Replace fuel nozzle 6 Inspect coils for soot build up 7 Inspect fuel tank and fittings for dirt and water inside 8 Inspect electrodes for damage 9 Inspect cir...

Страница 14: ...ctrical connections and fuel hose intact 7 Cover with waterproof plastic 8 Replace gasket on burner flange 9 Check parts inventory a New fuel filter b Replace lost or used fuel nozzles c Replace hose...

Страница 15: ...e coil and open the burner lid Carefully slide the nozzle pipe assembly downward and out until the assembly becomes free and lifts out Caution Be careful not to damage the ceramic insulators on the el...

Страница 16: ...16...

Страница 17: ...e Weak high voltage coil clean contacts 4 White smoke a Too much air b Not enough fuel 5 Relay indicator blink Clicking is heard a Not enough electrical power Minimum 110 VAC 6 No fuel pressure a Faul...

Страница 18: ...fficient flow of water Check flow requirements for size of hose 11 Underheating a Too much water flow Check flow requirements for size of hose b Low fuel pressure 120 psi at the regulator c Fuel nozzl...

Страница 19: ...ump won t prime a Obstructed fuel line b Air leak in fuel line c Fuel filter cap loose d Faulty fuel pump 18 Drip from bottom of combustion chamber Note Check smell and or feel of liquid If diesel is...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24 FUEL SYSTEM DIAGRAM AND PARTS LIST Part 1085 Part 1009 Part 1010 Part 1011 Part 1008 Part 1065 Part 1086 Part 2009...

Страница 25: ...RTS LIST Part 1085 Part 1168 Part 1068 Part 1021 Part 1087 Part 2028 Part 1056 Part 1075 Part 1040 Part 1076 Part 2006 Part 2003 Part 2004 Part 2005 Part 2007 Part 1025 Part 1088 Part 2008 Part 1079 P...

Страница 26: ...26 FUEL SYSTEM DIAGRAM AND PARTS LIST Part1087 Part 2010 Part 2011 Part 2005 Part 2012 Part 1085 Part 2013 Part 2014 Part 1086 Part 2009 Part 1009 Part 1011 Part 1010 Part 1019 Part 1073 Part 1020...

Страница 27: ...27 WATER PUMP DIAGRAM AND PARTS LIST Pump assembly Part 1001 Pump only Part 1101 Part 1013 Part 2021 Part 2022 Part 2029 Part 1031 Part 2023 Part 2024 Part 2025 Part 1082...

Страница 28: ...28...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...1 FUEL TANK DIAGRAM AND PARTS LIST Part 1081 Part 2006 Part 1035 Part 2026 Part 2026 Fuel tank only Part 1134 Specify size Fuel tenk assembly Part 1034 Part 1036 Part 2026 Part 1040 Part 2026 Part 203...

Страница 32: ...CLUDE 1018 FLOW SWITCH 1 2 INCH 1019 FUL FLO FUEL FILTER 1020 FUL FLO FILTER REPACEMENT CARTRIDGE 1021 DELAYED MAG VALVE 1021B 1121 MAG VALVE NEMA 4 ENCLOSURE 1022 SINGLE POLE SINGLE THROW RELAY 1023...

Страница 33: ...S 1058 1 4 INCH x 3 16 INCH BUSHING BRASS 1059 1 4 INCH HOSE BARB x 1 2 INCH FEMALE NPT BRASS 1060 1 4 INCH HOSE BARB x 1 4 INCH FEMALE NPT BRASS 1062 PRIMARY SENSOR WET WELL 1063 ELECTRICAL CONDUIT 1...

Страница 34: ...06 HOSE CLAMP 2007 NOZZLE HOLDER 2008 AIR DAM 2009 WATER TIGHT THERMAL RESET COVER 2010 AIR MIX ADJUSTMENT BAND 2011 BULKHEAD CONNECTOR 2012 BULKHEAD CONNECTOR RETAINING NUT 2013 SQUIRREL CAGE FAN 201...

Страница 35: ...TRIP 3008 GROUND BAR 3009 CONTROL BOW ASSEMBLY WITH COMPONENTS 3010 PUNCH CONTROL BOX ONLY 3011 1 2 INCH NPTM x 1 2 INCH BARB 3012 1 2 INCH NPTM x 1 2 INCH JIC 45 DEGREE 3013 1 2 INCH LONG NIPPLLE ORD...

Страница 36: ...ill filter body completely with clean diesel fuel allowing time for element to saturate filter 5 Replace rubber filter housing gasket 6 Reinstall filter housing lid 7 Reinstall large filter cap nut No...

Страница 37: ...ctric valve a Water should flow 12 Wait for output light to come on 13 Red lights come on a Check temperature both should be within 1 2 degrees of each other b Unit must level 14 Set secondary differe...

Страница 38: ...00 a Check for fuel leaks 23 Check secondary a Dial down until unit shuts off i ALL functions should stop ii No flame iii No water 24 Dial secondary set point back up a Unit should resume operation to...

Страница 39: ...until manifold is cool 32 Shut off water a Unhook water supply 33 Blow out with air a Not to exceed 100 psi 34 Open all ball valves a Drain and close Diver 1 b Open discharge 35 Pump 1 gallon of anti...

Отзывы: