![Custom Design & Fabrication Monkey PWH-100/3 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/custom-design-and-fabrication/monkey-pwh-100-3/monkey-pwh-100-3_operation-manual_2700785014.webp)
14
1.
Change fuel filter.
2.
Change fuel nozzle.
3.
Inspect blower for corrosion.
4.
Wash heater coil free of soot, using a wire brush or vacuum.
5.
Remove 3 nuts from burner mounting flange.
6.
Carefully remove burner and set aside. Leave electrical connections and
fuel hose intact.
7.
Cover with waterproof plastic.
8.
Replace gasket on burner flange.
9.
Check parts inventory.
a.
New fuel filter.
b.
Replace lost or used fuel nozzles.
c.
Replace hose fitting washers.
d.
Replace any lost or worn fittings.
WARNING!
DO NOT OPEN ELECTRICAL CLOSURE FITTINGS OR
PANEL COVERS. THIS PROCEDURE SHOULD ONLY
BE DONE BY A QUALIFIED ELECTRICIAN.
NOZZLE CHANGING PROCEDURE
1.
Disconnect Power Supply.