   CALIBRATION AND FEATURES

CALIBRATION INSTRUCTIONS

CRIMPER FEATURES

The easily removable Coupling Stop makes 
repetitive crimps faster by not having to visu-
ally align the 

fi

 tting before each crimp.

 

 

• 

After proper lubrication, place any standard die set in the 

compression cone and the pusher plate on top.

• 

Set the Micro-Crimp adjuster at “95”

• 

Press and hold the start switch bulb.

• 

If the ram extends and the crimper shuts off 

approximately 1 second after the dies are complete-
ly closed and the pump starts to build pressure, the 
crimper is correctly calibrated.

• 

If the time to shut off is not approximately 

1 second, the crimper must be recalibrated.  Reca-

li-

brate as follows:

• 

Hold the micrometer barrel with a 5/16 inch open end wrench and 

rotate the stem either in or out with a 5/32 inch hex key wrench.

• 

I

f the motor shuts off too quickly or before the dies are complete-

ly closed, rotate the stem in.

• 

If the motor does not shut off or shuts off in substantially more 

than 1 second, rotate the stem out.

The adjustable retraction stop limits the 
retraction of the ram to only the amount 
required to easily remove the hose and 

fi

 t-

ting.  This feature saves time when doing 
multiple crimps.

Содержание D165NP Series

Страница 1: ...1 Page D165NP SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL...

Страница 2: ...IMPER CRIMPER CAN PRODUCE 60 TONS OF FORCE KEEP HANDS AWAY FROM PINCH POINTS CONSULT CRIMP SPECIFICATIONS FOR CORRECT MACHINE SETTINGS AND CRIMP MEASUREMENTS ALWAYS WEAR EYE PROTECTION Rev 11 01 2005...

Страница 3: ...Diameter 2 Wire 1 1 4 Inch Maximum Hose Diameter 4 Wire 1 1 4 Inch Maximum Hose Diameter 6 Wire 1 Inch Crimper Depth 22 Crimper Width 12 5 Crimper Height 22 25 Weight 140 Lb Pump Electric Pump HP 1 HP...

Страница 4: ...TION Oil Fill Vent CapVent Plug Cylinder Top Pusher Hydraulic Pump Calibration Adjustment Screw Micrometer Micro Stop Switch Power Switch Circuit Breaker Retraction Stop Die Set Pusher Plate Start Sto...

Страница 5: ...g the crimper for the first time Lubricate all contact surfaces and place the Cone Insert any Small Series die set and the Standard Pusher in the crimper in the order shown Note that a hose and fittin...

Страница 6: ...osely in the cone insert Place the Pusher Plate on top of the die set Correct alignment of the hose and fitting in the die set is shown Reference crimp specifications for fit ting locations Slide the...

Страница 7: ...the pump starts to build pressure the crimper is correctly calibrated If the time to shut off is not approximately 1 second the crimper must be recalibrated Reca li brate as follows Hold the micromete...

Страница 8: ...s the die size stamped on the die ring Check crimper calibration and re calibrate if required Inadequate pump pressure Check oil level in the pump It should be 1 1 2 to 2 inches below the fill plug Re...

Страница 9: ...9 Page COMPONENT IDENTIFICATION...

Страница 10: ...10 Page COMPONENT IDENTIFICATION...

Страница 11: ...93744A160 3 8 Copper Flat Washer 1 11 91251A633 3 8 16 x 2 1 4 SHCS 1 12 SH940 35 375 Ram Wiper 1 13 102169 60 Ton Retaining Ring 1 60 Ton Cylinder Top Flange Assembly 102219 Item Part Number Descrip...

Отзывы: