Custom Crimp D165NP Series Скачать руководство пользователя страница 6

6

Page

   CRIMPING INSTRUCTIONS

Lubrication of the cone 
must be done prior using 
for the 

fi

 rst time.

.

Lubricate die 

fi

 ngers, all 

contact surfaces and die 
cones.

Use care to be certain 
that the die halves do not 
overlap.

Place the die set and hose 
and 

fi

 tting loosely in the 

cone insert.

Place the Pusher Plate on 
top of the die set.

Correct alignment of the 
hose and 

fi

 tting in the die 

set is shown.  Reference 
crimp speci

fi

 cations for 

fi

 t-

ting locations.

Slide the Pusher onto the stud 
on the hydraulic ram and press 
and hold the start switch until 
the motor shuts off.

Check the 

fi

 nished crimp 

diameter to be certain that it is 
within the crimp speci

fi

 cation 

limits.

 Adjust Micrometer 
per hose and 

fi

 tting 

speci

fi

 cation.

Содержание D165NP Series

Страница 1: ...1 Page D165NP SERIES HYDRAULIC HOSE CRIMPER OPERATORS MANUAL...

Страница 2: ...IMPER CRIMPER CAN PRODUCE 60 TONS OF FORCE KEEP HANDS AWAY FROM PINCH POINTS CONSULT CRIMP SPECIFICATIONS FOR CORRECT MACHINE SETTINGS AND CRIMP MEASUREMENTS ALWAYS WEAR EYE PROTECTION Rev 11 01 2005...

Страница 3: ...Diameter 2 Wire 1 1 4 Inch Maximum Hose Diameter 4 Wire 1 1 4 Inch Maximum Hose Diameter 6 Wire 1 Inch Crimper Depth 22 Crimper Width 12 5 Crimper Height 22 25 Weight 140 Lb Pump Electric Pump HP 1 HP...

Страница 4: ...TION Oil Fill Vent CapVent Plug Cylinder Top Pusher Hydraulic Pump Calibration Adjustment Screw Micrometer Micro Stop Switch Power Switch Circuit Breaker Retraction Stop Die Set Pusher Plate Start Sto...

Страница 5: ...g the crimper for the first time Lubricate all contact surfaces and place the Cone Insert any Small Series die set and the Standard Pusher in the crimper in the order shown Note that a hose and fittin...

Страница 6: ...osely in the cone insert Place the Pusher Plate on top of the die set Correct alignment of the hose and fitting in the die set is shown Reference crimp specifications for fit ting locations Slide the...

Страница 7: ...the pump starts to build pressure the crimper is correctly calibrated If the time to shut off is not approximately 1 second the crimper must be recalibrated Reca li brate as follows Hold the micromete...

Страница 8: ...s the die size stamped on the die ring Check crimper calibration and re calibrate if required Inadequate pump pressure Check oil level in the pump It should be 1 1 2 to 2 inches below the fill plug Re...

Страница 9: ...9 Page COMPONENT IDENTIFICATION...

Страница 10: ...10 Page COMPONENT IDENTIFICATION...

Страница 11: ...93744A160 3 8 Copper Flat Washer 1 11 91251A633 3 8 16 x 2 1 4 SHCS 1 12 SH940 35 375 Ram Wiper 1 13 102169 60 Ton Retaining Ring 1 60 Ton Cylinder Top Flange Assembly 102219 Item Part Number Descrip...

Отзывы: