 CC 25 CRIMPER CALIBRATION

Calibration Check:

Set the Micrometer at 000 and press and hold the
start switch.  If the dies are fully closed before the
crimper shuts off, the crimper is correctly
calibrated and does not require calibration..

Calibration:

If the crimper needs to be recalibrated, remove
the shoulder bolts holding the Micrometer in
place taking care not to lose the springs.

If the crimper does not shut off when the dies are
completely closed, loosen the jam nut on the end
of the micrometer and turn the set screw out
slightly.  Retighten the jam nut and check
calibration.

If the dies are not fully closed when the crimper
shuts off, the set screw should be turned in
slightly and calibration rechecked.

Note that when reinstalling the Micrometer, it
must be free to move slightly on the shoulder
bolts in order to release the micro switch located
in the base of the Micrometer mount.

Содержание CC25

Страница 1: ...CC25 HYDRAULIC CRIMPER OPERATORS MANUAL...

Страница 2: ...OF FORCE KEEP BOTH HANDS AWAY FROM PINCH POINTS CONSULT HOSE AND FITTING MANUFACTURER S SPECIFICATIONS FOR CORRECT MACHINE SETTINGS AND CRIMP MEASUREMENTS ALWAYS WEAR EYE PROTECTION Rev 3 2 2005 For...

Страница 3: ...3 Page CC25 COMPONENT IDENTIFICATION CRIMP ADJUSTMENT MICROMETER SYSTEM POWER SWITCH AND CIRCUIT BREAKER CRIMP HEAD RESERVOIR DRAIN REMOTE START STOP SWITCH OIL FILL PLUG BEHIND THE MOTOR...

Страница 4: ...ter 6 Wire 1 Maximum Die Opening Die Size Plus 18mm Maximum Opening w o Dies 86mm Length 21 Width 11 Weight 195 lb Electrical Power Requirement Std 110V Electrical Power Requirement Optional 220V 1 Ph...

Страница 5: ...te on Micrometer Settings Each 100 on the Micrometer represents 1 mm above the closed diameter of the die set For example with a 57mm die installed and the Micrometer set at 150 the finished crimp dia...

Страница 6: ...lace taking care not to lose the springs If the crimper does not shut off when the dies are completely closed loosen the jam nut on the end of the micrometer and turn the set screw out slightly Retigh...

Страница 7: ...between the master die fingers Be certain to replace the pads as they prevent dirt and debris from falling between the master die fingers and destroying the finished surfaces of the master dies With...

Страница 8: ...eter is the die size stamped on the die ring Incorrect setting of the micrometer Check hose manufacturer s specifications Inadequate pump pressure Check oil level in the pump It should be 1 1 2 to 2 i...

Страница 9: ...9 Page NOTES...

Отзывы: