CC 25 CRIMPER CALIBRATION
Calibration Check:
Set the Micrometer at 000 and press and hold the
start switch. If the dies are fully closed before the
crimper shuts off, the crimper is correctly
calibrated and does not require calibration..
Calibration:
If the crimper needs to be recalibrated, remove
the shoulder bolts holding the Micrometer in
place taking care not to lose the springs.
If the crimper does not shut off when the dies are
completely closed, loosen the jam nut on the end
of the micrometer and turn the set screw out
slightly. Retighten the jam nut and check
calibration.
If the dies are not fully closed when the crimper
shuts off, the set screw should be turned in
slightly and calibration rechecked.
Note that when reinstalling the Micrometer, it
must be free to move slightly on the shoulder
bolts in order to release the micro switch located
in the base of the Micrometer mount.