background image

 

 

5.3 

Basic functions 

 

Backlight

 

            Use the          button (briefly) to switch on background lighting   

 

Odograph (ODO) 

When using the odometer, press the three buttons

                                  simultaneously

 for 10s to reset ODO.

 

 

         

 

 

 

                                          Odometer   

 

Trip distance (TRIP)

 

In the trip distance state, press the        button for 2s,

 

Reset counter and time. 

 

 

 

 

单次里程

  Trip distance   

 

 

Average speed

AVG

 

Shows  the  average  speed  (average  speed=trip  distance  /  elapsed  time).  This  is  measured  with  a 

resolution of 0.1km/h (mil/h). Maximum is 99 km/h or 99.9mil/h. If you average this speed then we suggest 

you enter the next Olympics and represent the UK. Custom Built eBikes will sponsor you. 

 

 

 

                 

                                     

Average speed   

 

 

Elapsed Time

TIME

 

Shows how long you have been cycling for, 

 

Содержание VLCD-5

Страница 1: ...https custombuilt ebikes co uk VLCD 5 User Guide ...

Страница 2: ...1 Specification 1 Installation 2 Functions 3 Operation Procedure 4 5 1 Button Definition 4 5 2 Operation and setting 4 5 3 Basic functions 5 5 4 Hidden functions and to be showed 6 5 5 Fault Error code 9 5 6 Torque signal value shows 11 5 7 Initial value for torque signal 12 Contents ...

Страница 3: ... electric bicycle and record the trip distance Specification Type VLCD 5 Working voltage DC 11V 60V Max working current 70mA 11V 32mA 50V Display type 21 4 segment LCD Measuring the speed 1 12 pulses each round of wheel Working temperature 200 C 700 C Backlight White LED mode brightness 200cd m2 Dimension 102 5mm 74 5mm 28mm 102 5mm 75 5mm 28mm exclude thickness of Pedestal ...

Страница 4: ...h male to the 4 pin plug female 1 Orange RX 2 Brown TX 3 White Weak current 4 Green Power 5 Black Earth 6 Purple Brake VLCD pinout VLCD 5 Button control 5 core push male Mounting base Connect to the motor Connect to controller VLCD 5 6 pinplug female connector links unit to motor ...

Страница 5: ... among14 32 inch default is 26 inch 4 10 Speed Sensor Magnet Selection Select the magnetic steel number of the speed sensor default value is 1 4 11 Speed unit option Switch speed unit from Km h or Mil h fault is Km h 4 12 6km h function Select function of 6km default is OFF 4 13 Max speed setting reserved Select max speed 15 45km h Default is 25Km h 4 14 Assist ratio setting reserved Select the ra...

Страница 6: ...UR SPEED TURBO There are 4 levels of power assist none low medium high which are names Eco Tour Speed and Turbo Press the button to adjust the power assist from low to high Default is medium assistance speed ECO TOUR SPEED TURBO None Minimum Medium Max 3 Allows you to change the display ODO TRIP AVG TIME There are 4 modes odometer trip distance average speed elapsed time Press this button to adjus...

Страница 7: ...te press the button for 2s Reset counter and time 单次里程 Trip distance Average speed AVG Shows the average speed average speed trip distance elapsed time This is measured with a resolution of 0 1km h mil h Maximum is 99 km h or 99 9mil h If you average this speed then we suggest you enter the next Olympics and represent the UK Custom Built eBikes will sponsor you Average speed Elapsed Time TIME Show...

Страница 8: ...at with great power comes great responsibility There are 11 items you can play with odometer trip distance average speed elapsed time wheel diameter selection magnetic steel number selection speed units selection 6 Km h function selection top speed selection power adjustment selection mode selection The initial item is odometer Wheel diameter selection d1 Use the button to enter the speed units in...

Страница 9: ...l h Default is Km h Speed units interface 6 6km h walking mode Use the button to enter the 6 Km h walking mode press buttons to switch ON OFF Default is OFF Press button for 3s to start the motor running to assist your walking 6 Km h function selection SD Speed Limit Use the button to enter the speed limit selection press or buttons to adjust The default is 25KPH ...

Страница 10: ...buttons to switch between 6 and 35 with 25 being the default setting Power adjustment selection M Use the button to enter the mode submenu press button to switch between Japanese and European mode Default is Europe mode selection 3 7 Use the button to show the current software version ...

Страница 11: ...ial torque value which is for service inspection use only Odometer ODO Trip distance TRIP Average speed AVG TE1 TE One way time TIME Torque signal value display 5 7 Initial value for torque signal display Under submenu TE1 press again it shows initial torque value which is for service inspection use only The torque value is normal and the range is between 56 and 102 ERR 02 HALL Motor hall fault or...

Страница 12: ... Initial value for torque signal display ...