background image

6    SPRAYER OPERATION

28

6.6

CALIBRATION ____________________________________________________________

Practice with water - after you have followed all
recommendations, it is advisable to familiarize yourself
with the operation of the dedicated sprayer and sprayer
package. Practicing with plain water before the addition
of expensive and potentially destructive chemical
formulas (when mis-applied), can be smart and cost
effective.

To spray and spray accurately, you must have a set
standards to spray by.

The easiest method of calibration is to use as many fixed
constants that can be controlled, and then modify the tip
size & out-put pressure to lock in your desired application
rate.

When using the following formulas, the application rate
can be maintained by fixing the constants for each
category.

To properly calibrate the sprayer, the following
information is required.

Desired Application Rate - GPA (Gallons Per Acre) or
G/1000 ft

(Gallons per 1000 square feet).

Nozzle Spacing - Distance in inches between spray tips.

Desired Ground Speed - A fixed, ground speed is
recommended to maintain accurate calibration.

Tip Style - Type of pattern for particle distribution of
applicable chemical to be applied, i.e. (FL, XR, TT).

Tip Size - Determines volume per minute, per nozzle and
desired droplet (micron) size of spray carrier particles.

The following Formulas and conversion factors will help
you obtain the necessary information.

Abbreviations:

km - kilometer

m - meter

G - Gallon

l - Liter

GPA - Gallons per Acre

GPM - Gallons per Minute

MPH - Miles per hour

PSI - Pounds per square inch

W - Nozzle spacing in inches

Conversion Factors:

One Acre = 43,560 ft

2

 = 43.56 1000 ft

2

 = 0.405 hectares

One Hectare = 2.471 Acres

One GPA = 2.9 Fluid Ounces/1000 ft

2

 = 9.35 l/hectares

One G/1000 ft

2

 = 43.56 GPA

One Gallon = 4 Quarts = 8 Pints = 128 fluid ounces

One Gallon = 3.79 l = 0.83 Imperial Gallons

One Mile = 5,280 ft = 1.61 km = 1610 m

One PSI = 0.069 bar = 6.896 kilopascal

Fomulas:

GPM (per nozzle) = (GPA x MPH x W) / 5,940

GPM (per nozzle) = (G/1000 ft

2

 x MPH x W) / 136

GPA = (5,490 x GPM (per nozzle)) / (mph x W)

G/1000 ft

2

 = (136 x GPM (per nozzle)) / (mph x W) 

Содержание Spraytek DS175

Страница 1: ...machine should be trained in its proper use warned of its dangers and should read the entire manual before attempting to set up operate adjust or service the machine When Performance Matters GB Spray...

Страница 2: ...on Number 7 2 2 Engine Identification Numbers 7 2 3 SDI Sprayer Tank Identification Numbers 7 3 DECALS 3 1 Decals 8 3 2 Information and Operation Decals 10 3 3 Speed Chart Decals 10 4 CONTROLS 4 1 Ico...

Страница 3: ...r disconnect or bypass any switch 13 Do not change the engine governor setting or overspeed the engine 14 Carbon monoxide in the exhaust fumes can be fatal when inhaled Never operate the engine withou...

Страница 4: ...ly fastened in place By following all instructions in this manual you will prolong the life of your machine and maintain its maximum efficiency Adjustments and maintenance should always be performed b...

Страница 5: ...re chemicals near an open flame or spark which could ignite chemicals or chemical vapors Never work alone with harmful chemicals Always have a second person nearby in case of emergency 1 4 RECOMMENDED...

Страница 6: ...dures 4 Use an anti backflow protection device on fill hoses and water source outlets especially if using a public water system An air gap filler anti siphon is available as an optional accessory for...

Страница 7: ...correspondence concerning this vehicle 2 2 ENGINE IDENTIFICATION NUMBERS _________________________________________ The Truckster is equipped with a Suzuki three cylinder gas powered liquid cooled fou...

Страница 8: ...OT ALLOW UNTRAINED PERSONNEL TO OPERATE THIS VEHICLE 3 DO NOT MODIFY THIS VEHICLE WITHOUT MANUFACTURER S AUTHORIZATION 4 PLACE LOADS FOWARD OF REAR AXLE 5 TOP HEAVY LOADS CAN CAUSE UPSETTING DO NOT EX...

Страница 9: ...571 500 FOR ON ROAD USE THIS CUSHMAN UTILITY VEHICLE IS A FIRST STAGE UNIT THAT CAN BE COMPLETED BY FINAL STAGE MANUFACTURES FOR COMPLIANCE WITH FMVSS 571 500 CUSHMAN AND TEXTRON MAKE NO WARRANTY FOR...

Страница 10: ...3 11 0 2 8 4 8 7 6 11 4 2 9 4 9 7 8 11 8 3 0 5 1 8 1 12 2 3 1 5 3 8 3 12 6 3 2 5 4 8 6 13 0 3 3 5 6 8 9 13 4 3 4 5 8 9 1 13 8 2800 2900 3000 3100 3200 3300 3400 3500 3600 3 5 5 9 9 4 14 1 5 13 9 14 4...

Страница 11: ...all controls correctly Familiarize yourself with the icons shown above and what they represent Learn the location and purpose of all the controls and gauges before operating this tractor STOP Coolant...

Страница 12: ...r E Temperature Gauge F Turn Signal Indicator G Oil Pressure Light H Glow Plug Light J Service Brake Fluid Light K Parking Brake Light L High Beam Indicator M Ignition Switch N Gear Selector P Accesso...

Страница 13: ...inue to operate truck if light does not go out or comes on during operation H Glow Plug Light Does not have a function on this vehicle Glow plug light is used for diesel engines J Service Brake Fluid...

Страница 14: ...OFF LOW BEAM and HIGH BEAM Push switch up one detent for LOW BEAM or push switch up two detents for HIGH BEAM U Horn Button The horn button is located to the left of the steering wheel below the dash...

Страница 15: ...age and disengage sprayer pump Do not allow pump to run dry Permanent damage may result AC Agitation Control Handle Controls the amount of liquid passing through the nozzles allowing complete agitatio...

Страница 16: ...__________________________________ Cushman part number 4119057 1 Master Boom On Off 2 Boom 1 Left Boom 3 Boom 2 Center Boom 4 Boom 3 Right Boom 5 System Select Power Switch 6 Rate Adjust Override Swit...

Страница 17: ...em is functioning properly Stop the test and have the vehicle inspected and repaired if truck fails either test the engine does not start in test 1 the engine does start during tests 2 3 Perform actio...

Страница 18: ...uction or if the machine begins to vibrate abnormally Have the equipment repaired before resuming operation 10 Slow down and use extra care on hillsides Read Section 5 9 Use caution when operating nea...

Страница 19: ...Allow the engine to become warm and properly lubricated before operating at high RPM Figure 5A 5 5 PARKING_________________________________________________________________ To park the utility vehicle...

Страница 20: ...r downshifting 6 You can down shift from 4th to 3rd and from 3rd to 2nd and so on while the vehicle is moving and the engine s speed is decreasing NOTE Only downshift if the vehicle is at a complete s...

Страница 21: ...ssure is essential for maximum traction See 5 10 5 Use caution when changing speeds and or direction on slopes The large liquid payload reacts differently during vehicle movement Liquid moving inside...

Страница 22: ...n premature deterioration or failure Damage of this nature is not covered by the factory warranty b Do not use high pressure spray c Do not spray water directly at the instrument panel or any electric...

Страница 23: ...assing through the Venturi nozzle multiplier orifice It is recommended this valve remain fully open at all times even if there is alow tank liquid level 8 Jet Agitation Nozzle Assembly a eight head Ve...

Страница 24: ...r is supplied by the vehicle battery The sprayer to truck mounting style makes the two systems act as one complete machine Centrifugal Pump Lubrication lubrication for the impeller inside the pump hou...

Страница 25: ...mp and anti vortex area turning the agitation down or off with low fluid level in tank is not required 3 Spray Boom Inspect support frame and mounting hardware for loose damaged or missing components...

Страница 26: ...rge tip use adjust as necessary Move to the control console Listen carefully as you perform the next series of checks Push up on the pressure adjust toggle switch the Servo motor on the yellow striped...

Страница 27: ...move through foam generator cone feed tubes check each feed line check valve located just before each solenoid inlet Clean as needed Check supply fasteners on boom tubes for proper tightness and posi...

Страница 28: ...allons per 1000 square feet Nozzle Spacing Distance in inches between spray tips Desired Ground Speed A fixed ground speed is recommended to maintain accurate calibration Tip Style Type of pattern for...

Страница 29: ...hen using the formulas mentioned on the previous page The chart was taken from Page 10 of TeeJet Catalog 49A For a complete listing of tip options and charts call SDI or your local dealer for a new Te...

Страница 30: ...18 6 21 23 8 9 10 7 13 1 14 9 16 6 18 4 0 51 0 61 0 75 0 85 0 95 1 1 0 34 0 41 0 50 0 57 0 63 0 70 0 26 0 31 0 37 0 43 0 48 0 53 0 20 0 24 0 30 0 34 0 38 0 42 Blue XR8003 50 Mesh XR11003 50 Mesh 15 2...

Страница 31: ...5 acres Step 1 and you want 2 5 lbs of product per acre Step 2 8 75 acres x 2 5 lb sevin per acre 21 875 lb To apply the recommended application rate you will need to add 21 875 lb of Sevin for each f...

Страница 32: ...n the suction gate valve to the pump 6 Start the engine and using the governor hand control set the engine s RPM s to 3 000 RPM 7 Flip the pump switch to the ON position Look into the open lid remove...

Страница 33: ...evere damage to the turf because of rate changes from what your original rate was suppose to be The first 1 3 of the tank could apply more than the desired rate when heavy products are not fully suspe...

Страница 34: ...f oil is used may produce a putty like paste inside the tank a Flushing out residue of such chemicals after each load will help prevent accumulation b If water alone does not remove the build up add a...

Страница 35: ...NOTES 7 35 7 NOTES...

Страница 36: ...n Performance Matters Equipment from Jacobsen is built to exacting standards ensured by ISO 9001 and ISO 14001 registration at all of our manufacturing locations A worldwide dealer network and factory...

Отзывы: