Page L-5
Repair and Service Manual
B
B
BATTERIES AND CHARGING
Read all of Section B and this section before attempting any procedure. Pay particular attention to Notices, Cautions, Warnings and Dangers.
deposits neutralized and removed from the battery case
to prevent self discharge. The batteries should be
tested or recharged at thirty day minimum intervals.
Fig. 6 Freezing Point of Electrolyte
Battery Charging
The
battery charger is designed to fully charge the bat-
tery set. If the batteries are severely deep cycled, some
automatic battery chargers contain an electronic mod-
ule that may not activate and the battery charger will not
function. Automatic chargers will determine the correct
duration of charge to the battery set and will shut off
when the battery set is fully charged. Always refer to the
instructions of the specific charger used.
Before charging, the following should be observed:
Do not overfill batteries. The charging cycle will expel
electrolyte and result in component damage.
•
The electrolyte level in all cells must be at the
recommended level and cover the plates.
•
The charging must take place in an area that is well
ventilated and capable of removing the hydrogen gas
that is generated by the charging process. A
minimum
of five air exchanges per hour is
recommended.
•
The charging connector components are in good
condition and free from dirt or debris.
•
The charger connector is fully inserted into the
vehicle receptacle.
•
The charger connector/cord set is protected from
damage and is located in an area to prevent injury
that may result from personnel running over or
tripping over the cord set.
•
The charger is automatically turned off during the
connect/disconnect cycle and therefore no electrical
arc is generated at the DC plug/receptacle contacts.
In some portable chargers, there will be a rattle present in the
body of the charger DC plug. This rattle is caused by an inter-
nal magnet contained within the charger plug. The magnet is
part of the interlock system that prevents the vehicle from
being driven when the charger plug is inserted in the vehicle
charging receptacle.
AC Voltage
Battery charger output is directly related to the input
voltage. If multiple vehicles are receiving an incomplete
charge in a normally adequate time period, low AC volt-
age could be the cause and the power company should
be consulted.
TROUBLESHOOTING
In general, troubleshooting will be done for two distinct
reasons. First, a battery that performs poorly and is out-
side of the manufacturers specification should be identi-
fied in order to replace it under the terms of the
manufacturer’s warranty. Different manufacturers have
different requirements. Consult the battery manufac-
turer or the manufacturer’s representative for specific
requirements.
The second reason is to determine why a particular
vehicle does not perform adequately. Performance
problems may result in a vehicle that runs slowly or in a
vehicle that is unable to operate for the time required.
A new battery must
mature
before it will develop its
maximum capacity. Maturing may take up to 100
charge/discharge cycles. After the maturing phase, the
older a battery gets, the lower the capacity. The only
way to determine the capacity of a battery is to perform
a load test using a discharge machine following manu-
facturer’s recommendations.
1.100
1.120
1.160
1.200
1.240
1.280
1.140
1.180
1.220
1.260
1.300
-9
-15
-21
-26
-32
-37
-43
-48
-54
-60
-65
-71
E
L
E
C
T
R
O
L
Y
T
E
T
E
M
P
E
R
A
T
U
R
E
SPECIFIC GRAVITY ELECTROLYTE FREEZING POINT
O
C
+15
+5
-5
-15
-25
-35
-45
-55
-65
-75
-85
-95
O
F
NOTICE
Содержание Shuttle 2
Страница 6: ...Page iv Repair and Service Manual NOTES TABLE OF CONTENTS ...
Страница 195: ......