installation and Operating Instructions

electrical ambience heating

40 010 464

99 49

VARDA/NARVIK

IVAR

ALMA

OTHELLO

Содержание Varda

Страница 1: ...installation and Operating Instructions electrical ambience heating 40 010 464 99 49 VARDA NARVIK IVAR ALMA OTHELLO ...

Страница 2: ...ANING AND MAINTENANCE 10 6 1 Cleaning 10 6 2 Lamp replacement 10 DESCRIPTION OF THE STOVE DIMENSIONS fig 1 Varda Narvik fig 3 Alma fig 2 Othello fig 4 Ivar A Hot air outlet grille B Ashpan flap controls cover C Controls located on top canopy behind door D Door E Fan heater concealed behind grille F Flame effect window G Fan heater grill H Firebox door K Fan heater 253 754 654 820 720 796 696 12 69...

Страница 3: ...e effect which can be used with or without heating so that comforting effect may be enjoyed at any time of the year The flame effect is provided by low wattage motors and two or three 40 watt lamps Using the flame effect on its own therefore requires little electricity The controls are concealed behind the ashpan flap control cover A choice of 900 W or 1800W thermostatically controlled heat output...

Страница 4: ...tional fire safety regulations Ensure that all packaging items are removed read any warning labels carefully Retain all packaging untill installation is complete The heater must be used on an 230V supply and the voltage marked on the heater must correspond with the supply voltage Warning This appliance must be earthed When using electrical appliances basic precautions should always be followed to ...

Страница 5: ...rols are located on the top canopy behind the door fig 12 Connect the fire to your electricity supply 4 INSTALLATION Varda Narvik 4 1 INSTALLATION INSTRUCTIONS Have the stove installed by a qualified installer in conformance with national and local fire safety regulations Be sure that the chimney functions properly 4 2 INSTALLATION SPACE 4 3 LOCATION AND MINIMUM FREE SPACE Consult the installation...

Страница 6: ... heat output may be obtained by turning the knob to lower settings fig 15 5 5 THERMAL SAFETY CUT OUT A thermal safety cut out is incorporated in the heater to prevent damage due to overheating This can happen if the heat outlet was restricted in any way The heater will switch on once the obstruction has been removed and the heater has cooled If the cut out continues to operate intermittently the h...

Страница 7: ...uel assembly and slide up against the inner glass Replace the flame effect window fig 18 6 CLEANING AND MAINTENANCE Always disconnect from the power supply before attempting any maintenance 6 1 CLEANING Before commencing cleaning unplug the heater and allow it to cool The surface of the heater should be given an occasional wipe over with a soft damp cloth Do not use detergents abrasive cleaning po...