Chapter 5 Connector Descriptions
Parvus SWI-22-10
Curtiss-Wright
Page 58 of 107
MNL-0641-01 Rev A3
ECO-4823
Effective: 04 Oct 16
C
ONSOLE
P
ORT
On the SWI-22-10-10-10, the console port is located on a set of pins on J3.
J3
Signal
Function
B31
CONSOLE_RXD
Receive signal to the switch
B32
CONSOLE_TXD
Transmit signal from the switch
C32
CONSOLE_GND
Console signal ground
On the SWI-22-10-10-01, the console port is located on a set of pins on P4.
P4
Signal
Function
21
CONSOLE_RXD
Receive signal to the switch
23
CONSOLE_TXD
Transmit signal from the switch
24
CONSOLE_GND
Console signal ground
Z
EROIZE
P
ORT
On the SWI-22-10-10-10, the zeroize port is located on a set of pins on J3.
J3
Signal
Function
C30
ZEROIZE
Zeroize signal to the switch
C31
ZEROIZE_GND
Zeroize signal ground
On the SWI-22-10-10-01, the console port is located on a set of pins on P4.
P4
Signal
Function
20
ZEROIZE
Zeroize signal to the switch
22
ZEROIZE_GND
Zeroize signal ground
LED
P
ORT
On the SWI-22-10-10-10, the LED port is located on a set of pins on J2.
J2
Signal
B30
LED_ LOAD
C30
LED_ nRESET
B31
LED_CLOCK
C31
LED_PWR
B32
LED_DO
C32
LED_GND
On the SWI-22-10-10-01, the LED port is located on a set of pins on P7.
P7
Signal
19
LED_ LOAD
Содержание Parvus SWI-22-10-01
Страница 8: ...Parvus SWI 22 10 Curtiss Wright Page 8 of 107 MNL 0641 01 Rev A3 ECO 4823 Effective 04 Oct 16 ...
Страница 25: ...MNL 0641 01 Rev A3 ECO 4823 Effective 04 Oct 16 Page 25 of 107 7 end 8 copy running config startup config ...
Страница 107: ...MNL 0641 01 Rev A3 ECO 4823 Effective 04 Oct 16 Page 107 of 107 ...