Chapter 5 Connector Descriptions
Parvus SWI-22-10
Curtiss-Wright
Page 50 of 107
MNL-0641-01 Rev A3
ECO-4823
Effective: 04 Oct 16
C
HAPTER
5
C
ONNECTOR
D
ESCRIPTIONS
This chapter identifies connector part numbers, locations, and pinouts to facilitate fabrication of cables
that can connect to the SWI-22-10. The chapter describes the card-specific connectors for the SWI-22-
10-10 and SWI-22-10-01 and then describes the connectors common to both cards. Finally,
implementation information for the console, zeroize, and LED ports is provided.
SWI-22-10-10
C
ARD
-S
PECIFIC
C
ONNECTORS
P
ART
N
UMBERS
The following table shows the manufacturer part numbers for the SWI-22-10-10 connectors (identified in
Figure 15), together with the suggested mating connectors.
Connector
Part Number
Mating Connector
J2 & J3
Harwin M83-LML3M1N96-0000-000
Harwin M83-LFC1F1N96-0000-000 for 24- gauge CAT-5E wiring
Harwin M83-LFT1F2N96-0000-000 for flex cable or PCB mounting
Figure 15. SWI-22-10-10 Ethernet Connectors
D
ESCRIPTION AND
P
INOUTS
Connectors J2 and J3 form the Ethernet Switch Interface for the SWI-22-10-10.
20 Gigabit Ethernet Ports - The ports are numbered 1 through 20. Each port has four differential
matched pairs: A, B, C, and D (e.g., GBE20_A_P and GBE20_A_N).
RS-232 Port - Serial console interface
Zeroize - an external configuration erase function which returns the board to a default
configuration state.
Serial LED Interface
Содержание Parvus SWI-22-10-01
Страница 8: ...Parvus SWI 22 10 Curtiss Wright Page 8 of 107 MNL 0641 01 Rev A3 ECO 4823 Effective 04 Oct 16 ...
Страница 25: ...MNL 0641 01 Rev A3 ECO 4823 Effective 04 Oct 16 Page 25 of 107 7 end 8 copy running config startup config ...
Страница 107: ...MNL 0641 01 Rev A3 ECO 4823 Effective 04 Oct 16 Page 107 of 107 ...