Maintaining the L30 Atomizer
Several design factors are in place to help you maximize the life of the atomizer assembly. Some
factors are:
➢
The atomizer is precision balanced. The rough depressions on the face of the atomizer are
normal. These are the spots that were removed during balancing to equalize the mass of the
assembly while it is rotating. Balancing enables the atomizer to operate at high speed. If at any
time you detect a change in noise of the machine, turn OFF the Machine Switch immediately and
inspect the atomizer assembly. Be sure that all fasteners are tight including the ones on the motor
mounting bracket. A change in noise is a symptom of a loose atomizer assembly or one that is
out of balance.
Do not continue to operate the machine if you suspect the atomizer is out of
balance.
➢
A high capacity formulation filter is mounted on your machine. Filter must be installed for proper
operation of the unit. Replace filter cartridge as needed. See page 28.
➢
A filter is also installed inside the Flush Tank.
While the Dyna-Jet L30 Atomizer life can be prolonged with routine flushing and cleaning procedures,
there becomes a point when the atomizer can become clogged. The number of hours before
reaching this point depends greatly on some other key factors:
1) How well the formulation is filtered as it is poured into the tank
2) The quality of the formulation
3) Cleaning the formulation filter as required
4) Properly cleaning and handling of the atomizer sleeve
5) Protecting the atomizer when not in use
However, when your atomizer reaches the point of becoming clogged you must exchange the
atomizer assembly for a new clean and balanced assembly. Refer to the Atomizer Exchange
Program sheet that was shipped with your machine for details on how to handle an atomizer
exchange.
43
Содержание DYNA-FOG DYNA-JET L30 2 Series
Страница 21: ... ...
Страница 22: ...Terminal Strip Wire Connection Diagram 22 ...
Страница 24: ......
Страница 26: ... ...
Страница 28: ...28 ...
Страница 30: ...Pump Bracket Assembly L30 30 ...
Страница 38: ......
Страница 41: ...Pump Enclosure Wiring Diagram L30 41 ...
Страница 42: ...Remote Control Box Schematic L30 Series 2 42 ...