Water Does Not Heat At All

•  Check to see if the water level in the tank is in contact with the water level probe. If not, see 

Tank Does Not Fill

The water will not heat unless it is in contact with the probe.

•  If the water heats, but is not hot enough, see

Water Not Hot Enough

.

• If 

Ready to brew

 appears on the display, but the water is not hot, check the resistance across the leads of the 

temperature sensor. If the resistance is less than 10 k and the water is not hot, replace the temperature sensor. 
If the sensor resistance is above 10 k when the water is cool, replace the universal control module (UCM).

If 

Heating...

 appears on the display, but the water is not hot, follow the steps below. The following steps are 

performed with the rear toggle switch in the ON position.

1  Check for power across the terminals of the heating element(s). If power is being supplied, remove the wires 

and check for an open heating element.   

2  If there is no power to the element(s), trace the circuit back (using the ELECTRICAL SCHEMATIC) to the power 

DPSEUPmOEPVUXIFSFQPXFSJTMPTU*GUIFSFJTQPXFSJOUPUIFUSJBDCVUOPUPVUTFFUIFGPMMPXJOHTUFQ

3  If there is power into a triac, but not out, check for power at the gate terminal. Also check the wire to A2 from 

the UCM. If the connections are good and power is being supplied to the triac, but there is no voltage out 
of A2, replace the triac. If power is not being supplied from the UCM, but 

Heating...

 appears on the display, 

check the wiring from the UCM to the triac. If the wiring is OK, replace the UCM.

Water Too Hot (Boiling or Excessive Steaming)

  

1 If 

Over Temp Sensor

 or 

Ready to Brew

 appears on the display and the water is too hot, go to 

Over Temp 

Sensor Error Message

.

2  If the display reads 

Heating

DPOTUBOUMZmSTUDIFDLUPNBLFTVSFUIBUUIFUFNQFSBUVSFTFOTPSJTBUUBDIFEUJHIUMZ

to the tank and that heat sink compound was used. A properly mounted sensor should have a resistance of 
around 7 k when the water is hot. If not, replace the sensor.

3  Check to see if the universal control module (UCM) constantly has  power output to the triac, regardless of the 

resistance of the temperature sensor. If so, the UCM is probably bad. 

4  If the UCM is working properly, check for a bad triac.

Over Temp Sensor Error Message

This error message indicates that the universal control module (UCM) has detected a water overheating problem. 
The UCM is reading a water temperature in the tank above 210ºF (99°C). If the water temperature is too hot, but 

Heating...

appears on the display, see 

Water Too Hot

. Once the malfunction causing the error is corrected, the 

error message must be cleared. To reset the brewer and return to normal operation, turn the toggle switch on the 
back of the brewer to the OFF position for 5 seconds, then back on.

1  Check for power at the gate terminal on the triac. If there is no power at the triac gate terminal but the heating 

elements are always on, replace the triac.

2  Turn off power to the brewer and allow water tank to cool. Once cool, turn power back on while monitoring the 

triac gate voltage. During normal operation, power should be applied to the gate terminal, then drop to below 
1 Vac. The universal control module (UCM) should be replaced if power is applied to the triac gate constantly 
even though 

Ready to brew

 or 

Over Temp Sensor

 appears on the display.

3  If the UCM is operating normally, check for a false over-temp error caused by the temperature sensor. Check 

the resistance across the leads of the temperature sensor. If the resistance is less than 10 k when the water is 
cool, replace the temperature sensor.

TROUBLESHOOTING GUIDE

TG39

G3 BREWERS WITH TRIAC, TROUBLESHOOTING GUIDE-200F 

 

 

 

 

 

 011818A

IMPORTANT:

Before proceeding, make sure that the control panel temperature is adjusted to compensate 

for higher elevations. The factory setting is 200°F (92°C). Reduce the temperature setting 2°F (1°C) for 
every 1000 feet (300 m) of elevation above 4000 feet (1200 m).    

Содержание ALP3GT15A800

Страница 1: ...G3 Series Alpha FreshTrac Decanter Coffee Brewing System USER GUIDE READ AND SAVE THESE INSTRUCTIONS NOTICE TO INSTALLER Please leave this booklet with the machine 1 3 4 53 30 5 07 3 SFW...

Страница 2: ...ROW 3 OHFWULFDO 6FKHPDWLF XDO 9ROWDJH ES61 OHFWULFDO 6FKHPDWLF 9ROW ES62 7URXEOHVKRRWLQJ XLGH HQHUDO 7 7URXEOHVKRRWLQJ XLGH 7ULDF LUFXLW 7 7URXEOHVKRRWLQJ XLGH DUPHU LUFXLW 7 7URXEOHVKRRWLQJ XLGH UHVK...

Страница 3: ...and the monitoring system will continue to track freshness time Industry s most effective mineral tolerant design 6SHFL FDWLRQV 6HOHFWHG 0RGHOV OHFWULFDO 6XSSO 5HTXLUHPHQWV 02 6 5 37 21 3 6 92 76 036...

Страница 4: ...ve maintenance should be performed by an authorized Wilbur Curtis service technician 5P SFEVDF UIF SJTL PG mSF PS FMFDUSJD TIPDL 0 05 PQFO UIF TFSWJDF QBOFMT 5IFSF BSF OP VTFS serviceable parts inside...

Страница 5: ...Z QFSTPOT ZFBST BOE BCPWF XJUI SFEVDFE QIZTJDBM TFOTPSZ PS NFOUBM DBQBCJMJUJFT or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in...

Страница 6: ...ATIONS section for the correct size The water line should also be capable of being DPOUSPMMFE CZ B TIVU PGG WBMWF P OPU DPOOFDU UIF XBUFS MJOF UP B TBEEMF WBMWF PS OFFEMF WBMWF 4 OUFSOBUJPOBM SFRVJSFT...

Страница 7: ...to the brewer 6 Connect the wires on the power cable to the terminal block inside the brewer 7 Tighten the strain relief and replace the back cover 8 Connect the power cable wires to the terminals in...

Страница 8: ...re and the electrical TQFDJmDBUJPOT UIF XBUFS UBOL UZQJDBMMZ SFRVJSFT UP minutes to reach the factory set operating temperature When the water has heated Ready to brew will be displayed on the LCD scr...

Страница 9: ...DL VOUJM JU TUPQT 5IF CSFXFS XJMM CSFX DPGGFF CBTFE PO UIF TFUUJOHT QSPHSBNNFE JOUP UIF VOJWFSTBM DPOUSPM NPEVMF 6 5P DIBOHF UIF TFUUJOHT TFF UIF PROGRAMMING GUIDE TFDUJPO 5IF CSFXFS TIPVME CF 0 POmSN...

Страница 10: ...O BHBJO UP TFU BOE FYJU Warmer Temperature Control Factory setting 90 5IF XBSNFS UP CF BEKVTUFE NVTU CF PGG 1SFTT BOE IPME UIF EFTJSFE 8 3 3 CVUUPO VOUJM UIF QPXFS BEKVTUNFOU TDSFFO BQQFBST 1SFTT CVUU...

Страница 11: ...anter receiver XIJDI nBTIFT mWF UJNFT UP JOEJDBUF UIBU JU IBT been reset When the freshness time set on UIF 6 FYQJSFT UIF SFDFJWFS nBTIFT to inform the user that the coffee is no longer GSFTI 5IF XJMM...

Страница 12: ...ch The receiver should snap into place 3 Position the decanter on an Alpha FreshTrac brewer BOE SVO B UFTU CSFX UP NBLF TVSF UIF SFDFJWFS PQFSBUFT OPSNBMMZ 7FSJGZ UIBU UIF SFTI5SBD SFDFJWFS nBTIFT mWF...

Страница 13: ...brush for hard to clean areas Rinse with clean water then dry 3 Wipe the spray head area with a cloth soaked in a mild detergent solution Rinse with a cloth soaked with clean water removing any resid...

Страница 14: ...nters are dishwasher safe or may be hand washed To clean prepare a mild solution of detergent and warm water or urn cleaning solution intended for coffee decanters Cleaning the Glass Decanter Remove t...

Страница 15: ...Call Select Banner Name Select Warmers Auto Off Select Alpha series brewers only P Maintenance Select Beeper On Off Select FreshTrac Glass Select Display Messages Select Language Select Model Select S...

Страница 16: ...oose the desired setting Then press to set and exit Brew Count Odom When accessed this feature displays the total brew cycles since the odometer was last reset Press to exit or reset and exit Pre Infu...

Страница 17: ...r to choose the desired setting then press to exit Beeper On Off turns the beeper that is heard each time a button is pressed on or off the factory default is 0 0ODF BDDFTTFE QSFTT or to choose the de...

Страница 18: ...T UIF DIBODF UIBU UIF CSFX CBTLFU XJMM CF SFNPWFE UPP FBSMZ 5IF SBOHF JT 0 UP NJOVUFT 0ODF accessed press or to choose desired setting then press to exit Display Messages UVSOT EJTQMBZ PG UIF NFTTBHF...

Страница 19: ...Coffee Brewers ALPHA1 2 3 ROUGH IN DRAWING 120717A 17 63in 44 8cm 17 63in 44 8cm 17 13in 43 5cm ALP1GT ALP2GT ALP3GT 19 13in 48 6cm 1 25in 3 2cm 13 13in 33 3cm 8 75in 22 2cm 7 00in 17 8cm 20 25in 51...

Страница 20: ...RTS RECOMMENDED PARTS 110118B 20 11 7 8 25 5 26 9 27 21 18 13 14 12 15 3 28 24 17 2 19 29 23 30A 30B 16A 16B 22 10 ALPHA FRESHTRAC Main Chassis Exploded View Water tank assemblies Dual Voltage see sec...

Страница 21: ...120V 9W 20 WC 5310 TUBE 5 16 ID x 1 8W SILICONE GEN USE 21 WC 5231 COMPOUND HEAT SINK 5OZ 22 WC 103 SWITCH TOGGLE NON LIT DPST 25A 125 250VAC RESISTIVE 23 WC 6812 WARMER TOP ASSY 120V 24 WC 3503 LEG 3...

Страница 22: ...6 WC 1438 101 SENSOR TEMPERATURE TANK ITEM PART DESCRIPTION 7 WC 4394 GUARD SHOCK HEATING ELEMENT FOR SINGLE HEATING ELEMENT 8 WC 522 THERMOSTAT HI LIMIT HEATER CONTROL DPST 277V 40A 9 WC 37365 KIT F...

Страница 23: ...6 WC 1438 101 SENSOR TEMPERATURE TANK ITEM PART DESCRIPTION 7 WC 4394 GUARD SHOCK HEATING ELEMENT FOR SINGLE HEATING ELEMENT 8 WC 522 THERMOSTAT HI LIMIT HEATER CONTROL DPST 277V 40A 9 WC 37365 KIT FI...

Страница 24: ...ELECTRICAL SCHEMATICS ES61 1 5 53 4 5 ALPHA FRESHTRAC DUAL VOLTAGE...

Страница 25: ...ELECTRICAL SCHEMATICS ES62 1 5 53 4 5 ALPHA FRESHTRAC 220 VOLT...

Страница 26: ...S SFNPWFE UP BMMPX BDDFTT UP UIF WBMWF 3 3VO B CSFX DZDMF XIJMF NPOJUPSJOH UIF WPMUBHF BU UIF WBMWF DPJM UFSNJOBMT G WPMUBHF JT QSFTFOU PO UIF UFSNJOBMT ZPV TIPVME IFBS UIF WBMWF DMJDL PQFO DMPTFE BU...

Страница 27: ...UZ G UIF UBOL JT FNQUZ UIF SFTFU TXJUDI IBT QSPCBCMZ PQFOFE VQ EVF UP B MPX XBUFS MFWFM HP UP Water Tank Does Not Fill G UIFSF JT XBUFS JO UIF UBOL CVU OP QPXFS PVU QVTI JO PO UIF SFTFU TXJUDI CVUUPO...

Страница 28: ...enser Not Filled To Normal Level During Brewing IFDL UP NBLF TVSF UIBU UIF VOJWFSTBM DPOUSPM NPEVMF 6 CSFX CZQBTT BOE EJMVUJPO MFWFMT BSF TFU QSPQFSMZ 2 IFDL UP NBLF TVSF UIBU UIF nPX SBUF BOE XBUFS Q...

Страница 29: ...8BUFS MFWFM mMM FSSPS PS PWFSnPX 5IJT FSSPS NFTTBHF PDDVST XIFO UIF JOMFU WBMWF TPMFOPJE IBT CFFO PO UPP MPOH EVSJOH JOJUJBM mMM PS UBOL SFmMM 4FF UIF ERROR CODES TFDUJPO GPS UIF NBYJNVN UJNFT BMMPXFE...

Страница 30: ...und was used A properly mounted sensor should have a resistance of around 7 k when the water is hot If not replace the sensor 3 Check to see if the universal control module UCM constantly has power ou...

Страница 31: ...element If power is supplied to the element terminals but the element does not heat replace the element 3 Warmers Controlled by the Universal Control Module UCM If the warmer is not receiving power ch...

Страница 32: ...BD SFDFJWFS JT QSPQFSMZ QPTJUJPOFE TFF OPERATING INSTRUCTIONS 2 G UIF EFDBOUFS JT QSPQFSMZ QPTJUJPOFE TVCTUJUVUF JO B EJGGFSFOU SFTI5SBD SFDJFWFS UP TFF JG UIF CBUUFSZ IBT FYQJSFE 5ZQJDBM CBUUFSZ MJGF...

Страница 33: ...WKH KHDWLQJ WDQN KDV ULVHQ DERYH System Fault Messages An error message will appear on the screen in the event of a malfunction under the following conditions 1 8BUFS MFWFM PWFSnPX 5IJT FSSPS JOEJDBUF...

Страница 34: ...per installation of equipment This equipment must be installed by a professional technician and must comply with all local elec trical mechanical and plumbing codes Improper voltage Equipment must be...

Отзывы: