![Curtis Acuity 1030 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/curtis/acuity-1030/acuity-1030_manual_2699898031.webp)
28
Curtis 1030 Acuity Manual,
Rev. C
9 — SPECIFICATIONS
SPECIFICATIONS
The specifications for the Curtis Model 1030 Acuity are presented in Table 4.
CAN TERMINATION
CAN
MODEL NUMBER
VOLTAGE RANGE
RESISTOR 120Ω
CONNECTOR
1030-304
24 – 48 VDC
no Bullet
1030-310
24 – 48 VDC
no Deutsch
1030-306
24 – 48 VDC
yes Deutsch
1030-308
24 – 48 VDC
yes Bullet
1030-305
72 –144 VDC
no Bullet
1030-311
72 –144 VDC
no Deutsch
1030-307
72 –144 VDC
yes Deutsch
1030-309
72 –144 VDC
yes Bullet
Table 4 Specifications: 1030 Acuity
Electrical
Operating voltage range 24 – 48 VDC; 72 –144 VDC
Electrical isolation
500 VAC, per UL 583
Transients
IEC 6100-4-4, test level 2
Reverse voltage
Acuity will not be damaged if connected to the battery
protection
with inverted polarity.
Short circuit
All inputs and outputs (except CANbus) shall withstand
protection
continous short circuit to B– or B+.
CANbus Isolation
Eliminates ground loops that can cause component
damage as well as data errors due to differences in ground
potentials among the nodes on the CANbus.
Environmental
Operating/storage
–
30°C to 55°C
temperature range
Humidity
100% condensing, per IEC 60068-2-30, Db
Protection
IP67, per EN60529
Vibration
IEC 60068-2-6, Fc
Shock
IEC 60068-2-29, Eb
Chemical resistance
Immune to the effects of contact with battery electrolyte,
hydraulic fluid, water, baking soda.
EMC
Emission
EN55022 Class B (component test): EN12895 (vehicle test)
Immunity
EN61000-4-3 (component test): EN12895 (vehicle test)
ESD
EN61000-4-2 (component test): EN12895 (vehicle test)
Regulatory Approvals
UL (pending)
Recognition or component listing (UL 583)
9