![Curtis Acuity 1030 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/curtis/acuity-1030/acuity-1030_manual_2699898013.webp)
10
Curtis 1030 Acuity Manual,
Rev. C
3 — ACU-SET SOFTWARE
Handling historical data
The Historical Data screen allows the user to retrieve historical data from the
Acuity.
Four buttons near the top allow the user to handle the historical data.
Load History From Acuity
This function retrieves data records from the memory
of the Acuity. The number of records and the unique identifier of the Acuity
(and this battery) are displayed. There are three ways to view the data, each
with its own subscreen.
1
View Historical Data
Displays the raw data for each Acuity parameter in
tabular form. The battery parameters plotted using
Select Parameters to Plot
are:
State of Charge
Temperature
Ah Delivered / Returned
Percent Ah Returned
Estimated Ah Capacity.
2
Battery Cycles History
Displays a graphical representation of the battery
history data. Slide bars help select specific ranges of data to view and simplify
the identification of measurements of particular interest, such as when the state
of charge has fallen below 20%.
3
Battery Current Profile
Displays a bargraph showing the ranges over
which the ampere hours were consumed.
Examples of these three data displays are shown on the next page.