6 — CANopen COMMUNICATIONS
Curtis Model 3301T Digital Instrumentation – September 2021
pg. 50
TPDO1
Byte(s)
Description
0
The following bits indicate various types of data:
• 0–1: The
:
–
00b: High.
–
01b: Standard.
–
10b: Economy.
–
11b: Turtle.
• 2: Lift lock status. 0b = inactive.
• 3: Parking status. 0b = inactive.
• 4: Seat status. 0b = inactive.
• 5: Pump status. 0b = off.
• 6–7:
Reserved
.
1
The BDI percentage.
2–5
The keyswitch hour meter data.
The 3301T hour meters provide a resolution of 0.1 hours.
For example, F423Fh indicates 99999.9 hours.
6
The vehicle unlock control status. 0b = lock, 1b = unlock.
7
Reserved
.
Byte(s)
Description
7
The following bits indicate the statuses of various display elements:
• 0: Whether the oil filter icon is displayed. 1b = displayed.
• 1–3: The
:
–
001b = Neutral.
–
010b = Forward.
–
011b = Backward.
–
100b = Left turn.
–
101b = Right turn.
–
Other values: A direction icon is not displayed.
• 4–7: The
(reach trucks and order pickers screen):
–
0001b: Inactive lift.
–
0010b: Lift up.
–
0011b: Lift down.
–
0100b: Lift left.
–
0101b: Lift right.
–
0110b: Lift up and left.
–
0111b: Lift up and right.
–
1000b: Lift down and left.
–
1001b: Lift down and right.
–
1010b: Rotate clockwise.
–
1011b: Rotate counterclockwise.
–
1100b: Shift left.
–
1101b: Shift right.
–
Other values: A forklift status icon is not displayed.