50
Curtis 1356/1356P CAN Expansion Module Manual,
Rev. A
ENCODER MONITOR MENU
ALLOWABLE
PARAMETER
RANGE
DESCRIPTION
Pulse Counts
-2
29
–
4
2
29
-1
Current encoder pulse counts.
Negative counts indicate the encoder is running
in the reverse direction of the zero position.
RPM
0 – 65535 rpm
Displays RPM, when the encoder type
is configured as RPM mode.
Position
-32.768 – 32.767 m
Displays position, when the encoder type
is configured as Position mode.
Negative counts indicate the encoder ia running
in the reverse direction of the zero position.
7 — PROGRAMMER: MONITOR MENUS
POWER SUPPLY OUTPUT MONITOR MENU
ALLOWABLE
PARAMETER
RANGE
DESCRIPTION
+5V
0.0 – 6.3 V
Voltage of the +5V output.
+12V
0.0 – 16.0 V
Voltage of the +12V output.
EXT Current
0 – 250 mA
Combined current of the ex12V and +5V
power supplies.
BATTERY VOLTAGE MONITOR MENU
ALLOWABLE
PARAMETER
RANGE
DESCRIPTION
Battery Voltage
0.0 – 120.0 V
Voltage of the battery.
HOUR METER MONITOR MENU
ALLOWABLE
PARAMETER
RANGE
DESCRIPTION
Hours
0 – 65535 h
Present hours of the hour meter. The hour meter
runs all the time the 1356 /1356P is powered on.
Minutes
0 – 59 min
Present minutes of the hour meter.
Fault Menu
The Curtis programmer provides a convenient way to access fault information;
see Section 6: Faults and Diagnostics. The programmer displays the faults by
name. It displays all faults that are currently set and also a history of all the
faults that have been set since the history log was last cleared.