3 — PROGRAMMABLE PARAMETERS
3
PROGRAMMABLE PARAMETERS
The 1204M/05M/09M/21M controllers have a number of parameters that
can be adjusted using a Curtis programming device. These programmable
parameters allow the vehicle’s performance to be customized to fit the needs
of specific applications.
The programmable parameters are displayed in five submenus within the
Program menu (on the 1311 handheld programmer) or the Parameters menu
(on the 1313 handheld programmer or 1314 PC Programming Station).
Voltage
Battery Voltage
Undervoltage Cutback
Undervoltage Cutback Rate
Undervoltage Cutoff
Current
Main Current Limit
Plug Current Limit
Speed
Accel Rate
Quick Start
Max Speed
Rev Speed
Throttle
Throttle Type
Throttle Deadband
Throttle Max
Throttle Map
Misc
HPD
Variable Plug
Boost
Contactor Protection
Main Drop Delay
Rev Input / Main Driver
Description of the parameter’s
function and, where applicable,
suggestions for setting it
⇓
Allowable range
in the
programmer’s units
⇓
Parameter name
as it appears in the
programmer display
⇓
The individual parameters are presented as follows in the parameter charts:
Max Speed
0–100 %
Defines the maximum motor speed at full throttle, as % PWM.
Curtis 1204M/1205M/1209M/1221M Manual
17