13
Remove the injector with a 7 mm spanner and replace the
injector with the ones from the spare set, with corresponding
diameters suitable to the type of gas that is going to be used,
according to the information chart (which is also supplied in
the gas conversion kit).
To Replace the Oven/Grill Injectors
Removal of the Grill Burner Injector
The grill injector can be accessed by removing the
single screw on the tip of the burner (as shown).
Remove the screw and pull the grill burner towards
the front of the cooker, the injector will be revealed
on the rear surface of the cavity.
Screw
Adjusting the Reduced Flame Position
For the oven burner, operate the oven burner at minimum position for 5 minutes, then open and close the oven
door 2-3 times to check the burner’s flame stability.
Reduced flame position adjustment is not required for grill burners.
Make sure that the appliance is unplugged from the electric
mains and the gas supply is open.
• For conversion from LPG to NG, the position of the
adjustment screw must be loosened (turn anti-clockwise).
• For conversion from NG to LPG, the screw must be
tightened (turn clockwise).
Adjustment
Screw
Thermostatic oven valve
* All images are for indication only; please refer to your individual unit for actual item.
Removal of the Oven Burner Injector
Remove the two screws that hold the burner cover in
place and lift out cover. Pull back the spark module
to remove it, then pull back the thermocouple to
remove it.
Remove the oven burner by moving it right and left
in the burner box to reveal the injector. Remove the
injector with a 7mm spanner and replace it with one
from the spare set , with corresponding diameters
suitable to the type of gas that is going to be used,
according to the information chart (which is also
supplied in the gas conversion kit).
Injector
Oven burner
(removed from fitting)
CFSGSV16_WH16_IB.indd 13
04/04/2016 17:43
Содержание ESSENTIALS CFSGSV16
Страница 31: ...CFSGSV16_WH16_IB indd 31 04 04 2016 17 44 ...