background image

1/2" DIA. 

THRU HOLE

SUPPLIED NUT

SMALL

BUSHING

SUPPLIED TEST SWITCH/

INDICATOR LIGHT

TY-WRAP

SW INDICATOR

LARGE 

BUSHING

PLASTIC

TUBE

SW INDICATOR

PLASTIC

TUBE

LARGE

BUSHING

EM DRIVER

 SMALL

BUSHING

SW LEADS

TIE WRAP

7/8" DIA THRU

      HOLE

BALLAST

CHANNEL

 COVER

 FIXTURE

DIFFUSER 

    LENS

93071446

ILLUSTRATION 2

ILLUSTRATION 1

93071446

93071446

ILLUSTRATION 3

TY-WRAP

UL SWITCH

COVER

UL SWITCH

COVER

ILLUSTRATION 4

EM DRIVER

LED mtg plt

(lens not shown)

TYPICAL LED

   LIGHTING 

    FIXTURE

  SWITCH 

INDICATOR

"CAUTION"

   LABEL

"STATUS"

  LABEL

93071865

Mounting Height: This product meets or exceeds the NFPA  minimum light requirements 

with all loads, down to the smallest rated lamp load, at heights up to 28.4ft (8.4m). 

Many factors influence emergency illumination levels, such as the lamp load selected, 

luminare design, and environmental factors, therefore end use verification is necessary. 

For field installations,when the attached luminaire is mounted at heights greater then 

28.4ft (8.7m), the level of illumination must be measured in the end application to ensure 

the requirements of NFPA 101 and local codes are satisfied.

WIRING

Step 5.  Select correct wiring diagram to connect the emergency driver to the LED load, AC LED driver and Switch. Make sure all connections are in accordance with the National 

Electrical Code and any local regulations.

Step 6.  Install in a visible location the labels “CAUTION” & “STATUS” (see illustration 4).
Step 7. 

After installation is complete, supply AC power to the emergency ballast and join the invertor connector.

Step 8.  At this point, power should be connected to both the AC driver and the emergency driver, and the charging indicator light should illuminate indicating the battery is 

charging.

Step 9.  A short-term discharge test may be conducted after the emergency ballast has been charging for one hour.
Step 10.  Charge for 24 hours before conducting a long-term discharge test. Refer to “Operation” section below

Note: Make sure the necessary branch circuit wiring is available. An unswitched source of power is required.

          The emergency ballast must be fed from the same branch circuit as the AC ballast.

ALB

ALB

EC-160127003

4/28/16

1

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

SHT 1

1 SHTS

--

-

--

-

93071433

93071433

1

ILL-DIA WIRING EV10

ALB

04/28/16

ALB

4/28/16

---

ALB

4/28/16

NTS

REV.

DRAWING NO.

SIZE

SCALE

PART NO.

FINISH:

MATERIAL:

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

DIMENSIONS IN INCHES
DIMENSIONS IN [ ] IN MM
CONFORMS TO ASME Y14.5M
DO NOT SCALE PRINT

DRAWN BY:

THIRD ANGLE PROJECTION

CHECKED BY:

ENGINEERING:

CATALOG NO.

CRITICAL DIMENSIONS

C

UNSPECIFIED TOLERANCES: INCHES

X.XX= 0.12 

FRACTIONS= 1/32 ANGULAR TOLERANCE= 1

RED
RED
WHT/RED
BLACK
VIOLET (+)
BROWN (-)

WHITE

WHT/BLK

BLUE

YEL/BLK

YELLOW

LED (+)

LED (-)

AC DRIVER (-)
AC DRIVER (+)

BLACK
WHITE

 PLD10

EM LED 

DRIVER

LED LOAD

AC DRIVER

HOT

COMMON

VIOLET (+)
BROWN (-)

WALL SW

CONVERTER BATTERY CONN.

TEST SW/LED INDICATOR

RED
RED

BLACK

VIOLET (+)
BROWN (-)

WHITE

WHT/BLK

BLUE

YEL/BLK

YELLOW

LED (+)

LED (-)

 PLD10

EM LED 

DRIVER

LED LOAD

HOT

COMMON

VIOLET (+)
BROWN (-)

CONVERTER BATTERY CONN.

TEST SW/LED INDICATOR

CAP

RED
RED

WHT/RED

BLACK
VIOLET (+)
BROWN (-)

WHITE

WHT/BLK

BLUE

YEL/BLK

YELLOW

LED (+)

LED (-)

AC DRIVER (-)

AC DRIVER (+)

SW 1

WHITE

 PLD10

EM LED 

DRIVER

LED LOAD

AC DRIVER

HOT

COMMON

VIOLET (+)
BROWN (-)

CONVERTER BATTERY CONN.

TEST SW/LED INDICATOR

AC DRIVER (-)

AC DRIVER (+)

LINE 1

LINE 2

HOT

SW 2

EMERGENCY BACK-UP ONLY

EMERGENCY BACK-UP & AC DRIVER

EMERGENCY BACK-UP, AC DRIVER

                   AND STEP DIMMING

THIS ILL IS ON INSTRUCTION SHEET 93070924.

EMERGENCY DRIVER AND AC DRIVER MUST BE FED FROM THE SAME BRANCH CIRCUIT

TYPICAL SCHEMATICS ONLY. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS

PLD9-2H

PLD9-2H

EM LED

EM LED

DRIVER

DRIVER

PLD9-2H

PLD9-2H

EM LED

EM LED

DRIVER

DRIVER

Отзывы: