Ed. 0121 - 70702601 REV00 Rounding machine - Preinstallation
1
2
Fig. 8
Fig. 9
Installation
Electrical connection
Before installing the appliance,
check that systems
comply with the regulations in force
in the country
where it is going to be used and
with the specifica-
tions indicated on the appliance rating plate
on the LH
side of the product.
•
single-phase machines
have
the connection cable and
the plug already fitted
; for the connection, just insert the
plug in a socket of suitable capacity
Fig. 8
•
three-phase machines
have
the power cable already
installed; a plug (not supplied) must be fitted to it
of
suitable capacity. This operation must be carried out
by
qualified personnel.
For a correct electrical connection, the appliance must:
•
be included in an
equipotential system
Fig. 9
in com-
pliance with the legislation in force. This connection must be
made between the various devices with the terminal marked
with the equipotential symbol
. The cable must have a
maximum cross-section of 10 mm
2
(in compliance with
IEC EN 60335-2-42:2003-09) and must be yellow-green;
•
must be
grounded
to the mains (green-yellow wire);
•
must be connected to a
circuit breaker
in compliance with
the regulations in force (0.03A A type);
•
must be connected to an
omnipolar circuit breaker
allowing complete disconnection in overvoltage III category
conditions.
The Manufacturer accepts no liability for failure to comply with
the above.
Installation
The following pages show the electrical diagrams:
please refer to the one of the specific model to
connect.
If required, the cable must be replaced by the Dealer or its technical service or by a person with similar qualifications to
prevent any risk.
Electrical data
Model
Supply
V
Motor
kW
Current
draw
A
Cable type
n x mm
2
RND 280
AC 230V/50Hz
0.37 kW
2.7
3x1.5
AC 3 N 400V/50Hz
0.37 kW
1.8
4x1.5
RND 800
AC 230V/50Hz
0.37 kW
2.7
3x1.5
AC 3 N 400V/50Hz
0.37 kW
1.8
4x1.5