Ed. 0121 - 70702570 REV02 Pizzaform - Pre-installation
D Electrical connection (qualified electrician’s inspection)
√
For a correct connection during the installation:
•
provide a socket
connecting to the electrical network near the
product.
•
machines
NOT
for the American market - UL
have
the power
cable already installed; a plug (not supplied) must be fit-
ted to it
of suitable capacity. This operation must be carried out
by qualified personnel.
•
machines for the American market - UL
have NO power cable
and NO plug.
Both are NOT supplied, must be fitted by qualified
personnel and must be only
of the type stated
in the table.
•
check that the systems in the room comply with the legal
provisions in force in the country of use
and meet the spec-
ifications on the serial number plate. For a correct electrical con-
nection, the appliance must:
•
be included in an
equipotential system
in compliance with
the legislation in force. This connection must be made be-
tween the various devices with the terminal marked with the
equipotential symbol
. The cable must have a maximum
cross-section of 10 mm
2
(in compliance with IEC EN 60335-2-
42:2003-09) and must be yellow-green;
•
must be
grounded
to the mains (green-yellow wire);
•
must be connected to a
thermal differential switch
in com-
pliance with the regulations in force (0.03A A type);
•
must be connected to an
omnipolar circuit breaker
allowing
complete disconnection in overvoltage III category conditions.
Electrical data
Model
Pizzaform
Supply
V
Upper
h.elem.
W
Lower
h.elem.
W
Motor
W
Tot. kW
Absorbed
current
A
Cable type*
n x mm
2
Cust. panel
prot.
nxA
30
single-phase 230V/50Hz
1790
1790
370
3.95
17.2
3x2,5
2 x 20
three-phase 3x230V/50Hz
1790
1790
550
4.13
10.4
4x1,5
3 x 16
three-phase N/50Hz
1790
1790
550
4.13
6.0
5x1
4 x 16
single-phase 208V/60Hz
1790
1790
550
4.13
19.9
3xAWG14
2 x 25
three-phase 3x208V/60Hz
1790
1790
550
4.13
11.5
4xAWG14
3 x 16
35
single-phase 230V/50Hz
1790
1790
370
3.95
17.2
3x2,5
2 x 20
three-phase 3x230V/50Hz
1790
1790
550
4.13
10.4
4x1,5
3 x 16
three-phase N/50Hz
1790
1790
550
4.13
6.0
5x1
4 x 16
single-phase 208V/60Hz
1790
1790
550
4.13
19.9
3xAWG14
2 x 25
three-phase 3x208V/60Hz
1790
1790
550
4.13
11.5
4xAWG14
3 x 16
40
single-phase 230V/50Hz
2400
2400
750
5.55
24.1
3x2
.5
2 x 25
three-phase 3x230V/50Hz
2400
2400
750
5.55
13.9
4x2,5
3 x 16
three-phase N/50Hz
2400
2400
750
5.55
8.0
5x1
.5
4 x 16
single-phase 208V/60Hz
2400
2400
750
5.55
26.7
3xAWG14
2 x 32
three-phase 3x208V/60Hz
2400
2400
750
5.55
15.4
4xAWG14
3 x 16
45
single-phase 230V/50Hz
2900
2900
750
6.55
28.5
3x4
2 x 40
three-phase 3x230V/50Hz
2900
2900
750
6.55
16.4
4x2,5
3 x 16
three-phase N/50Hz
2900
2900
750
6.55
9.5
5x1,5
4 x 16
single-phase 208V/60Hz
2900
2900
750
6.55
31.5
3xAWG12
2 x 40
three-phase 3x208V/60Hz
2900
2900
750
6.55
18.2
4xAWG12
3 x 20
50
single-phase 230V/50Hz
2900
2900
750
6.55
28.5
3x4
2 x 40
three-phase 3x230V/50Hz
2900
2900
750
6.55
16.4
4x2,5
3 x 16
three-phase N/50Hz
2900
2900
750
6.55
9.5
5x1,5
4 x 16
single-phase 208V/60Hz
2900
2900
750
6.55
31.5
3xAWG12
2 x 40
three-phase 3x208V/60Hz
2900
2900
750
6.55
18.2
4xAWG12
3 x 20
Checks before purchasing
* These cables can only be used if their length does not exceed 2 m between the point where the cable or its protection enters the
appliance and the entry into the plug.
Содержание PZF/30
Страница 21: ...21 Ed 0121 70702570 REV02 Pizzaform Pre installation 3N400 50 60Hz Wiring diagrams ...
Страница 29: ...29 Ed 0121 70702570 REV02 Pizzaform Pre installation Fig 18 4 7 8 6 5 5 sec 9 10 Final operations ...
Страница 31: ...31 Ed 0121 70702570 REV02 Pizzaform Pre installation Fig 21 5 8 7 9 6 Final operations ...
Страница 39: ...39 Ed 0121 70702570 REV02 Pizzaform Pre installation ...