12
ELECTRICAL CONNECTION
Before installing the appliance, check that sys-
tems comply with the regulations in force in
the country where it is going to be used and
with the specifications indicated on the appliance
rating plate on the RH side of the oven.
The appliances, depending on the model, are provided
with:
■
without either power cable or plug
;
■
power cable and Schüko plug already installed.
Appliances are supplied without either power cable
or plug
The electrical connection must be carried out
exclusively by qualified personnel after read-
ing the safety warnings at the beginning of the
manual.
The cable must be only of the type stated and the
plug fitted to it must be suitable for the consump-
tion and connection of the oven to the electrical
mains.
If required, the cable can be replaced by the
Dealer or its technical service or by a person
with similar qualifications to prevent any risk.
Fig.10 - Fig.11
To connect the cable to the appliance, remove the back
panel of the control compartment, let the cable through
the cable clamp provided and connect it to the terminal
block correctly. The following pages show the electrical
diagrams: please refer to the one of the specific model
to connect.
For a correct electrical connection, the appliance must:
■
must be
grounded
to the mains (green-yellow
wire);
■
must be connected to a
thermal differential
switch
in compliance with the regulations in force
(0.03A A type);
x6
M5x12
L
N
AC 230
N
L
IN
OUT
N:
L:
A
B
C
D
Fig.10
Installation |
Electrical connection
earth
neutral