28
Fig. 13
Fig. 14
Oven type
Supply V
Power kW
Average
consumption kWh
Absorption A
Cable type
Customer panel prot.
nxA
435
single-phase 230V
5.8
3.5
25.2
H07RN-F 3G4
2x32
three-phase 400V
8.4
H07RN-F 5G1
4x16
three-phase 230V
14.6
H07RN-F 4G1,5
3x16
three-phase 208V
5.8
3.5
16.1
15/4 SOOW CABLE
3x16
635
three-phase 400V
8.4
5.0
12.1
H07RN-F 5G1,5
4x16
three-phase 230V
21.1
H07RN-F 4G2,5
3x25
three-phase 208V
8.5
5.1
23.6
13/4 SOOW CABLE
3x25
635L
three-phase 400V
8.6
5.2
12.4
H07RN-F 5G1,5
4x16
three-phase 230V
21.6
H07RN-F 4G2,5
3x25
three-phase 208V
8.6
5.2
23.9
13/4 SOOW CABLE
3x25
935
three-phase 400V
12.6
7.6
18.2
H07RN-F 5G2,5
4x20
three-phase 230V
31.6
H07RN-F 4G4
3x32
three-phase 208V
12.8
7.7
35.5
9/4 SOOW CABLE
3x40
Installation
•
must be connected to an
omnipolar circuit breaker
allowing complete disconnection in overvoltage III category
conditions.
The Manufacturer accepts no liability for failure to comply with
the above.
If required, the cable can be replaced by the Dealer or its
technical service or by a person with similar qualifica-
tions to prevent any risk.
Содержание Donatello DN 435
Страница 9: ...9 Ed 0121 70702530 REV02 Donatello Pre installation CP Donatello DN 435 oven technical data triple ...
Страница 13: ...13 Ed 0121 70702530 REV02 Donatello Pre installation CP Donatello DN 635 oven technical data triple ...
Страница 17: ...17 Ed 0121 70702530 REV02 Donatello Pre installation CP Donatello DN 635L oven technical data triple ...
Страница 21: ...21 Ed 0121 70702530 REV02 Donatello Pre installation CP Donatello DN 935 oven technical data triple ...
Страница 38: ...38 Notes ...
Страница 39: ...39 Ed 0121 70702530 REV02 Donatello Pre installation CP ...