© 2012 Cummins-Allison Corp.
29
Comm Report
This field enables Normal Communications Report format or Wedge Communications Report
format. When connected to the Cummins Allison Software Wedge, be sure to set Port 1 or Port 2
to standard computer interface (COMP) and COMM Report to “Wedge.” In all other
circumstances, set COMM Report to “Normal.”
Options
The magnetic head function (MAG) or UV Option (includes UV and FL) for suspect document
detection can be enabled if the magnetic head and UV are installed, otherwise it should be
disabled. For JetCount model 4020, both MAG and UV should be disabled. For JetCount model
4021, UV should be disabled
SD Function Control
Enables or disables the ability to view and change SD sensitivity settings during normal
operation. Key Status and Options affect this feature. Please refer to the following chart.
(For information on how to handle a suspect document during processing, see
Key Lockout Option
SD Function
Control
Results
SD
MAG UV
MAG UV
OFF
ON/OFF
ON
ON
•
SD is locked ON or OFF.
•
If SD is locked ON, cannot change sensitivity
level of Hi-Med-Low. Able to view, but not
change sensitivity settings.
•
If SD is locked OFF, cannot view or change
sensitivity settings.
ON
ON
ON
OFF
•
SD key is locked ON or OFF.
•
If SD is locked ON, Hi-Med-Low level can be
changed and sensitivity settings can be
changed.
•
If SD is locked OFF, cannot view or change
sensitivity settings.
ON
OFF/ON
OFF/ON
ON
•
If Mag or UV Option is OFF, Key Lockout for that
option is automatically set to OFF. However, if
the Option is changed to ON, Key Lockout will
not revert to the ON setting.
•
If Option is set to OFF, cannot change or view
sensitivity settings for that option.
•
If Option is set to ON, can view and change
sensitivity settings.