30
TARGET BIN SCALE RF rev.09
TARGET BIN SCALE RF
10. TECHNICAL SPECIFICATIONS
Type .................................................
TARGET BIN SCALE RF
Main supply fuse F1 ............................
1A, fast-blow
Main supply/frequency .......................... 115/230V+10% -20%, 20VA, 50/60Hz
14Vdc output ..................................... 14 Vdc±10%, regulated,100mA max.
14Vdc output fuse F2 ..........................
1A, fast-blow
Housing ............................................. IP54, plastic casing
Operating temperature .......................... 0 to 40°C (32 to 104°F)
Storage temperature ............................. -15 to 50°C (32 to 104°F)
Ambient relative humidity ...................... max. 95%
Alarm Relay ........................................ 10mA to 2A, 24 Vac or dc max.
Pollution degree ................................... 2
Altitude ............................................. Up to 2000m
Installation Category: ............................ Class II
Type .................................................
TRB-8
Main supply fuse F2 .............................
1A, fast-blow
Main supply/frequency .......................... 115/230V+10% -20%, 20VA, 50/60Hz
Relay Output 1-8: ................................ 10A Res, 1/2HP 250VAC
Output fuses
F1, F3, F4, F5, F6, F7, F8, F10: ............. 10A slow blow
Housing ............................................. IP54, plastic casing
Operating temperature .......................... 0 to 40°C
Storage temperature ............................. -15 to 50°C
Ambient relative humidity ...................... max. 95%
Pollution degree ................................... 2
Altitude ............................................. Up to 2000m
Type .................................................
LCJB-8
Input ................................................. 5 @ 15 VDC 100 mA MAX
Housing ............................................. IP54, plastic casing
Operating temperature ......................... -40 to 40°C (-40 to 104°F)
Storage temperature ............................ -40 to 50°C (-40 to 122°F)
Type .................................................
LCT-3
Input ................................................. 11 @ 20 VDC 140mA MAX
Housing ............................................. IP54, plastic casing
Operating temperature .......................... 0 to 40°C (32 to 104°F)
Storage temperature ............................. -15 to 50°C (5 to 122°F)
Ambient relative humidity ...................... max. 95%
The room temperature where the controller is located must always
remain between 32° and 104°F (0 and 40°C). For indoor use only !
11
TARGET BIN SCALE RF rev.09
TARGET BIN SCALE RF
5.4. Feed Line Settings
This section shows how to specify the loca-
tion of each feed line and how to select the
timer they are using. Note that each auger
and each feed line operates in timer mode.
These outputs can either use individual time
clocks or they can share common timers. Re-
fer to section 6.2.3 to program the timer.
Worksheets are provided at the end of
this manual to write down your time
clock & relay settings.
1. From the main menu, select:
» 7. Installation*
» 5. Feed Line Set.
» x. Select the desired feed line
*This menu is only accessible from the installer
mode (see sec. 5.2).
FeedLine 1
Relay
: 5
Clock:
: 3
2. Set the following parameters:
Relay —
Specify which relay the feed line
uses.
Clock —
Specify which time clock the feed
line uses. *
This parameter is available if the "Clock
Schedule" option is disabled in the Installation
Settings (see section 5.3). If this option is enabled,
time clocks must be assigned separately for each
day of the week. Refer to section 6.2.1 to make this
assignment.
3. Proceed in similar fashion to assign a relay
and a time clock to all feed lines.
5.5. Bin Settings
This section shows how to set the low feed
level of each bin. The controller sounds an
alarm when the feed level gets lower than
this limit.
1. From the main menu, select:
» 7. Installation*
» 3. Bin Settings
» x. Select the desired bin
*This menu is only accessible from the installer
mode (see sec. 5.2).
7.3.1 Bin 1 Settings
Low level
13 kg
Fill Del
5 min
2. Set the following parameters:
Low Level —
Set the feed level below which
an alarm sets off. You can also disable this
alarm condition by decreasing the parameter
value to "None"
Fill Delay —
A feed delivery is likely to be
composed of multiple and successive dumps.
The fill delay allows the controller to combine
the weight of all feed dumps in a single fill-
ing value. The fill delay actually represents
the time allowed between two dumps for
the controller to consider both dumps as be-
ing part of the same filling. The Fill Delay is
launched at the end of each dump. Set it to
the desired value.
Note that the augers of the bin that
is being filled are stopped during the
filling process and until the end of the
fill delay.