18
TARGET BIN SCALE RF rev.09
TARGET BIN SCALE RF
6.2.1.2. Assigning Scheduled
Time Clock
When time clocks are used on a daily basis,
the bin augers and feed lines can use differ-
ent time clocks during the week. In order to
use variable time clocks, activate the
"Clock
Schedule"
option in the Installation menu (see
section 5.3).
Bins with multiple augers : If a bin uses
multiple augers, you must program the
timers in a way that there is only one
auger running at a time! In other words,
if a bin has 2 augers, the augers must
not use a common time clock.
Worksheets are provided at the end of
this manual to write down your time
clock settings.
1. From the main menu, select:
» 3. House
» 5. Clock Schedule*
*This menu is available if the "Clock Schedule"
option is enabled in the installation menu (see sec-
tion 5.3).
3.5 Clock Schedule
Sunday
Clock
Auger 1
1
FeedLine 1
2
FeedLine 2
3
2. Select the timer that is used by each bin
auger & feed line separately for each day of
the week.
6.2.2. Programming the Flexible
Feed Schedule
a) Setting the Schedule
If the controller uses a flexible feed schedule,
you must specify the frequency at which
feeding days are skipped. Refer to section
6.1.1 for further information about the fol-
lowing parameters and refer to section 5.3
to enable this type of schedule.
Press the corresponding shortcut
key to access the following menu.
1. From the main menu, select:
» 3. House
» 3. Schedule
3.3 Schedule
Frequency:
1/8
Days Left:
6
Next Day Skip: Tue.
2. Set the following parameters:
The parameters below will be displayed
if the feed schedule is set to "Skip" in
the Installation menu (sec. 5.3).
Frequency —
This is the frequency at which
a feeding day is skipped. It can be adjusted
from one day out of 2 to 8 days. Set the
frequency to the desired value.
Days Left —
This is the number of days
that are left before the next skipped day. If
required, you can modify the number of days
before the next skipped day.
Next Skipped Day —
The next feeding day
to be skipped is displayed. This day is auto-
matically defined according to the skipping
frequency and to the days left before the next
skipped day. It cannot be modified.
23
TARGET BIN SCALE RF rev.09
TARGET BIN SCALE RF
7.2.2. Feed Remaining in the Bins
Current amount of feed remaining
1. From the main menu, select:
» 2. Feed Inventory
» x. Select the desired bin
» 1. Information
2.1 Bin Info
Remaining 1000kg
Consump. 1000kg
Filling 500kg
The amount of remaining feed is displayed.
History of remaining feed
The controller has an history menu which
contains amount of remaining feed from the
past 60 days.
1. From the main menu, select:
» 2. Feed Inventory
» x. Select the desired bin
» 2. History
» 3. Remaining
2.2.3 Remaining
200X/01/31 11:59PM
Remain: 1000kg
2. The history of remaining feed is displayed.
Press the down-arrow key to scroll down
through this history.
7.2.3. Bin Consumption
Bin consumption menus give the daily amount
of feed that has been taken away from the
bins today.
Today's consumption
1. From the main menu, select:
» 2. Feed Inventory
» x. Select the desired bin
» 1. Information
2.1 Bin Info
Remaining
1000 kg
Consump.
1000 kg
Filling
500 kg
2. The amount of feed that was taken away
from the selected bin today is displayed.
Consumption history
The controller has an history menu which
contains the amount of feed that was taken
away the bins from the past 60 days.
1. From the main menu, select:
» 2. Feed Inventory
» x. Select the desired bin
» 2. History
» 1. Consumption
2.2.3 Consumption
200X/01/31 11:59PM
Cons.: 1000kg
2. The consumption history is displayed.
Press the down-arrow key to scroll down
through this history.