Part No. 4801-1020 Rev 2-2015
Super-Saver XL 250 Heater
– 120 Volt, 60Hz, ETL
Page
14
of 22
9. Servicing Instructions: SPI Model
9.1
Standing Pilot Ignition System
IMPORTANT!
Inspect and check operation of this appliance monthly. Follow the
instructions below. If a problem is detected, contact a qualified
technician to make any necessary repairs.
In an effort to minimize the time required to trouble shoot this system:
A.
Turn off the gas supply at the main gas valve.
B.
Disconnect electric power to system at main fuse of circuit breaker, if connected.
C.
Visually inspect equipment for apparent damage. Check wiring for loose
connections.
D.
Inspect pilot assembly for dust buildup.
E.
After performing the above inspections, restore gas supply, light pilot light, and
restore electric power to the equipment. Close thermostat contacts to cycle the
system.
DANGER!
ALL CIRCUITS HAVE LINE VOLTAGE